§ 13-811 — Fruit ripening process
Code of Ordinances of the City of New Haven, Connecticut (Supp. No. 31: codified through Ordinance No. 2025-0018, enacted September 11, 2025) · New Haven Code of Ordinances § 13-811
Corpus is an independent public-information project, not the official City of New Haven website. Stable reference: corpuslaw.us/code/72c58172-8dcc-4f6e-8c3a-de88f662a151
Sec. 13-811. - Fruit ripening process.
(1) General. This section shall apply to the process of ripening green bananas or citrus fruits in tightly closed rooms heated with direct fired heaters and shall include those processes where ethylene gas is introduced into the room to assist the ripening process. (2) Permit required. No person shall conduct any of the processing described in this section unless he holds a permit. (3) Use of ethylene. No person shall use or permit the use of ethylene in fruit ripening process unless: (a) The location of buildings in which fruit ripening processes utilizing ethylene are conducted shall be approved by the fire marshal. (b) Ethylene shall be introduced by some means under positive control and measured so that the quantity introduced does not exceed one (1) part ethylene to one thousand (1,000) parts of air. (c) Containers storing ethylene shall be built in accordance with nationally recognized good practice. (d) Containers other than those connected for use shall be stored outside of the building or in a special building except that not more than two portable ICC containers not connected for use may be stored inside the building premises. Such inside rooms or portions of buildings used for storage of these containers shall be within a portion of the building which is one-story in height, without cellar or basement, of construction having a fire resistance rating of not less than one hour and with openings to other parts of the building protected by approved self-closing fire doors or stationary wired glass windows in approved metal frames. Adequate ventilation shall be provided and the rooms or portions of buildings shall not be used for any other purpose. (e) Ethylene piping shall be of iron pipe. Flexible connectors and hose, when used, shall be of approved type. Tubing shall be of brass or copper with not less than 0.049 inch wall thickness. (4) Electrical equipment. No person shall conduct or permit fruit ripening to be conducted in any structure unless: (a) Electrical wiring and equipment shall be installed in accordance with nationally recognized good practice. (b) Lighting shall be by electricity. (5) Heating. No person shall conduct or permit any fruit ripening to be conducted in any structure unless: (a) Heating of ripening rooms shall be by indirect means with low pressure steam hot water; or warm air; approved electric heaters; or approved gas heaters or approved kerosene heaters both of which shall have sealed combustion chambers. (b) Steam and hot water pipes and radiators shall have a clearance of at least one inch to combustible material. (c) Gas heaters and their vents shall be installed in accordance with nationally recognized good practice. Gas heaters shall be equipped with an automatic pilot device to shut off the gas supply whenever the flame is extinguished. (d) Burners for gas or kerosene heaters shall be installed so that air for combustion is taken from outside the ripening room and the products of combustion are discharged to the outside. (e) Kerosene heaters shall be installed in accordance with the applicable provisions of section 13-825. (f) Electric heaters shall be of a type having no exposed surface at a temperature higher than eight hundred degrees Fahrenheit (800°F.) and with thermostatic elements which produce no sparks and shall be of a type approved for use in hazardous locations. (g) A protective guard shall be provided around any heater to prevent the possibility of its being knocked over by other equipment such as vehicles or lift trucks. (6) Open flames. No person shall conduct or permit any fruit ripening to be conducted in violation of the following: (a) Open flame heaters and open lights shall not be permitted in ripening rooms. (b) "No Smoking" signs shall be posted at every entrance and smoking shall be prohibited in the ripening rooms. (7) Housekeeping. Any person operating a fruit ripening process shall frequently clear ripening rooms of all combustible material.
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.
