§ 5.1 — General Standards
Code of Ordinances of the City of New Haven, Connecticut (Supp. No. 31: codified through Ordinance No. 2025-0018, enacted September 11, 2025) · New Haven Flood Damage Prevention Code § 5.1
Corpus is an independent public-information project, not the official City of New Haven website. Stable reference: corpuslaw.us/code/6cb4df7f-6301-4bef-9980-f1523b44594b
5.1. - General Standards.
5.1.1 In all areas of special flood hazard the following provisions shall apply: New construction or substantial improvement of any structure shall have the lowest Finished Living Space elevated at least two feet above the base flood elevation. Fully enclosed areas built below the BFE shall only be used for parking, building access or egress, or limited storage in accordance with provisions in 5.3.2. 5.1.2 New construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; 5.1.3 New construction, and substantial improvements shall be constructed with materials resistant to flood damage; 5.1.4 New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; 5.1.5 Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within components during flooding conditions; 5.1.6 New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; 5.1.7 New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the system into flood waters; 5.1.8 On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding; 5.1.9 In any portion of a watercourse which is altered or relocated the flood carrying capacity shall be maintained; 5.1.10 Manufactured homes. New manufactured homes (including "mobile" homes and recreational vehicles placed on a site for one hundred eighty (180) consecutive days or longer), (including, but not limited to, manufactured homes located outside a manufactured home park or subdivision, in a new manufactured home park or subdivision, in an existing manufactured home park or subdivision, in an expansion to an existing manufactured home park or subdivision, or on a site in an existing manufactured home park in which a manufactured home has incurred substantial damage as a result of a flood) to be placed or substantially improved shall be: 5.1.10.1 Elevated so that the lowest floor is two feet above the base flood elevation; 5.1.10.2 Placed on a permanent foundation which itself is securely anchored and to which the structure is securely anchored so that it will resist flotation, lateral movement, and hydrostatic and hydrodynamic pressures. Anchoring may include, but not be limited to, the use of over-the-top or frame ties to ground anchors; 5.1.10.3 Installed using methods and practices which minimize flood damage. Elevation construction standards include piling foundations placed no more than 10 feet apart, and the provision of reinforcement for piers more than six feet above ground level. 5.1.10.4 Adequate access and drainage should be provided. 5.1.11 Recreational vehicles. Recreational vehicles must be on site for fewer than one hundred eighty (180) consecutive days and be fully licensed and ready for highway use or meet the elevation and anchoring requirements of a manufactured home. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions. 5.1.12 Compensatory storage. The water holding capacity of the floodplain, except those areas which are tidally influenced, shall not be reduced. Any reduction caused by filling, new construction or substantial improvements involving an increase in footprint to the structure, shall be compensated for by deepening and/or widening of the floodplain. Storage shall be provided on-site, unless easements have been gained from adjacent property owners; it shall be provided within the same hydraulic reach and a volume not previously used for flood storage; it shall be hydraulically comparable and incrementally equal to the theoretical volume of flood water at each elevation, up to and including the 100- year flood elevation, which would be displaced by the proposed project. Such compensatory volume shall have an unrestricted hydraulic connection to the same waterway or water body. Compensatory storage can be provided off-site if approved by the municipality. 5.1.13 Equal conveyance. Within the floodplain, except those areas which are tidally influenced, as designated on the Flood Insurance Rate Map (FIRM) for the community, encroachments resulting from filling, new construction or substantial improvements involving an increase in footprint of the structure, are prohibited unless the applicant provides certification by a registered professional engineer demonstrating, with supporting hydrologic and hydraulic analyses performed in accordance with standard engineering practices, that such encroachments shall not result in any (0.00 feet) increase in flood levels (base flood elevation). Work within the floodplain and the land adjacent to the floodplain, including work to provide compensatory storage shall not be constructed in such a way so as to cause an increase in flood stage or flood velocity. 5.1.14 Underground storage tanks and above-ground storage tanks. New and expanded underground storage tanks are not permitted in the area of special flood hazard. Above-ground tanks shall be installed at or above base flood elevation plus two feet and shall be anchored to prevent flotation, collapse, and lateral movement. Anchored tanks must have the top of the fill pipe located at least two feet above the BFE and have a screw fill cap that does not allow for the infiltration of flood water. 5.1.15 Hazardous materials. All new development or substantial improvements with hazardous mat rials must follow the requirements and limits outlined in the current Connecticut State Building Code. The development or expansion of the following uses are prohibited in the Special Flood Hazard Area. 5.1.15.1 Motor vehicle maintenance, recycling, storage, sales or fueling: 5.1.15.2 All uses outlined in the Zoning Ordinance of the City of New Haven, Article V. Section 42 Use Regulations for businesses and industrial districts in Table 3 under "T. Industrial," except Manufacturing, subject to other provisions of this and not analogous to any use specifically mentioned in this ordinance and in particular § 46, outdoor activities and storage, waste, dumping, quarries and § 48, performance standards; Artisan Manufacturing; and antenna or wireless sites and transmitting towers for radio or television stations. 5.1.15.3 Oil, fuel, or gas refining or underground storage of such materials. 5.1.15.4 Laundry or dry cleaning. 5.1.16 Critical facilities. New critical facilities, with the exception of wastewater and stormwater management devices and facilities and any other publicly-regulated utility, are not permitted in the area of special flood hazard (SFHA). 5.1.17 Portion of structure in flood zone. If any portion of a structure lies within the Special Flood Hazard Area (SFHA), the entire structure is considered to be in the SFHA. The entire structure must meet the construction requirements of the flood zone. The structure includes any attached additions, garages, decks, sunrooms, or any other structure attached to the main structure. Decks or porches that extend into a more restrictive flood zone will require the entire structure to meet the standards of the more restrictive zone. 5.1.18 Structures in two flood zones. If a structure lies within two or more flood zones, the construction standards of the most restrictive zone apply to the entire structure (i.e., V zone is more restrictive than A zone; structure must be built to the highest BFE). The structure includes any attached additions, garages, decks, sunrooms, or any other structure attached to the main structure. (decks or porches that extend into a more restrictive zone will require the entire structure to meet the requirements of the more restrictive zone.) 5.1.19 No structures entirely or partially over water. New construction, substantial improvements, and repair to structures that have sustained substantial damage cannot be constructed or located entirely or partially over water unless it is a functionally dependent use or facility. 5.1.20 Prohibited Uses: The following uses are prohibited under all conditions in the Special Flood Hazard Area: 5.1.20.1 Uses that store, produce, or utilize hazardous materials as outlined in 5.1.15. 5.1.20.2 Critical facilities 5.1.20.3 Salt storage piles 5.1.20.4 Underground storage tanks 5.1.20.5 All solid waste uses as defined in Section 46 of the New Haven Zoning Ordinance, as amended from time to time.
(Ord. No. 1980, 9-6-23; Ord. No. 2023-0041, Sch. A, 12-4-23; Ord. No. 2024-0022, 10-21-24)
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.