§ 5.4 — Specific Standards in coastal high hazard areas, Zones VE and Coastal AE
Code of Ordinances of the City of New Haven, Connecticut (Supp. No. 31: codified through Ordinance No. 2025-0018, enacted September 11, 2025) · New Haven Flood Damage Prevention Code § 5.4
Corpus is an independent public-information project, not the official City of New Haven website. Stable reference: corpuslaw.us/code/cb296aee-13a8-4edb-bd59-70b4df998e9f
5.4. - Specific Standards in coastal high hazard areas, Zones VE and Coastal AE.
Located within the Special Flood Hazard Areas (SFHA) are areas designated as Coastal High Hazard Areas. These areas have additional flood hazards associated with wave wash, erosion scour, and high wind. Therefore, the following provisions shall apply: 5.4.1 Fill. There shall be no fill used as structural support. The fill must wash out from storm surge, thereby rendering the building free of obstruction, prior to generating excessive loading forces, ramping effects, or wave deflection. 5.4.1.1 The Building Inspector shall approve design plans for non structural fill only after the applicant has provided an analysis by an engineer, architect, and/or soil scientist, which demonstrates that the following factors have been fully considered: 5.4.1.2 Particle composition of fill material does not have a tendency for excessive natural compaction; and 5.4.1.3 Volume and distribution of fill will not cause wave deflection to adjacent properties; and 5.4.1.4 Slope of fill will not cause wave run-up or ramping.
(Ord. No. 2024-0022, 10-21-24)
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.