5.3. - Specific Standards.
The following provisions shall apply to all areas of special flood hazard addition to all general standards contained in Section 5.1: 5.3.1 Lowest Floor Renovations. Regardless of whether a project meets the "substantial improvement" threshold, under no circumstances should a non-residential use below the BFE plus two feet requirement be converted into a residential use. 5.3.2 Fully Enclosed Areas Below Base Flood Elevation. New construction or substantial improvements of buildings that include fully-enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the automatic entry and exit of flood waters to equalize hydrostatic flood forces on exterior walls. An enclosed area below the base flood elevation that meets the design criteria specified below is not considered the lowest floor of the structure. 5.3.2.1 Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: 5.3.2.1.1 Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 5.3.2.1.2 The bottom of all openings shall be no higher than one foot above the slab elevation and set at or above the exterior ground elevation so as to permit free drainage away from the structure; and 5.3.2.1.3 Openings shall be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions. 5.3.2.3.2 Electrical, plumbing, and other utility connections are prohibited below two feet above the base flood elevation; and 5.3.2.3.3 Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator). 5.3.3 Floodways. Located within areas of special flood hazard established in Section 3.2 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris and potential projectiles and have erosion potential, no encroachments, including fill, new construction, substantial improvements and other developments shall be permitted unless certification (with supporting technical data) by a registered professional engineer is provided demonstrating through hydrologic and hydraulic analysis performed in accordance with standard engineering practices that proposed encroachments shall not result in any (0.00 feet) increase in flood levels during occurrence of the base flood discharge. 5.3.4 Dry Flood Proofing. In lieu of being elevated, non-residential structures may be dry flood-proofed to two (2.0) feet above the BFE provided that together with all attendant utilities and sanitary facilities the areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, and provided that such structures are composed of structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall review and/or develop structural design specifications and plans for the construction and shall certify that the design and methods of construction are in accordance with acceptable standards of practice for meeting the provisions of this section. Such certification shall be provided to the Building Inspector on the FEMA Floodproofing Certificate, Form 81-65. 5.3.5 Other. 5.3.5.1 All new construction or substantial improvement shall be located 25 feet landward of the reach of the Connecticut Coastal Jurisdiction Line as defined in Connecticut General Statutes 22a-359 as amended by Public Act 12-101; 5.3.5.2 All new construction or substantial improvement shall be elevated so that the bottom of the lowest structural horizontal member (excluding pilings or columns) is located no lower than two feet above the base flood level, with all space below the lowest supporting member open so as not to impede the flow of water or dry flood proofed; 5.3.5.3 All new construction or substantial improvement shall be securely anchored on pilings or columns; 5.3.5.4 All pilings or columns and the attached structures shall be anchored to resist flotation, collapse, and lateral movement due to the effect of wind and water loads acting simultaneously on all build-ing components. The anchoring and support system shall be designed with wind and water loading values which equal or exceed the 100-year mean recurrence interval (one percent annual chance floods and winds); 5.3.5.5 A registered professional engineer or architect shall review and/or develop structural design specifications and plans for construction and shall certify that the design, specifications and methods of construction are in accord with acceptable standards of practice for meeting the provisions contained in Sections 5.3 of this ordinance; 5.3.5.6 There shall be no alteration of sand dunes which would increase potential flood damage; 5.3.5.7 Non-supporting breakaway walls, lattice work or mesh screening may be allowed below the base flood elevation provided it is not part of the structural support of the building and is designed so as to breakaway, under abnormally high tides or wave action, without damage to the structural integrity of the building on which it is to be used and provided the following specific design specifications are met: 5.3.5.7.l Design safe loading resistance of each wall shall not be less than 10 nor more than 20 pounds per square foot; or 5.3.5.7.2 If more than 20 pounds per square foot, a registered professional engineer or architect shall certify that the design wall collapse would result from a water load less than that which would occur during the base flood event, and the elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components during the base flood event. Maximum wind and water loading values to be used in this determination shall each have one percent (1%) chance of being equaled or exceeded in any given year (100-year mean recurrence interval). 5.3.5.8 If breakaway walls, lattice work or screening are utilized, the resulting enclosed space shall not be designed to be used for human habitation but shall be designed to be used only for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises. 5.3.5.9 Prior to construction, plans for any structures that will have breakaway walls, lattice work or screening must be submitted to the Building Inspector for approval. 5.3.5.10 Any alteration, repair, reconstruction, or improvement to a structure shall not enclose the space below the lowest floor except with breakaway walls, lattice work or screening as provided for in Sections 5.3.5.7—5.3.58.
(Ord. No. 1980, 9-6-23; Ord. No. 2024-0022, 10-21-24)
Ask a question about New Haven law
Corpus searches the New Haven sections it holds and shows the ones that match, with their citations. Free, no sign-in.