Sec. 7-101. - Water heaters.
(a) Water heaters shall not be installed in bathrooms or in rooms less than 600 cubic feet in size unless adequate air intake and ventilation is provided. All water heaters must be provided with a positive automatic shutoff valve that will not allow gas to pass through the main burner in the event of a pilot outage. All water heaters must be equipped with an approved automatic opening and closing temperature and pressure relief valve. All water heaters installed in a garage area shall be at least 18 inches from floor level to the burner. (b) All water heaters must be vented, and the vent must be so installed, regardless of horizontal or vertical height or lengths, that all products of combustion are carried to the outside air. Where there is a flue liner from a furnace or a space heater, the water heater must be vented into this liner or into a separate flue or vent. Water heaters should not be vented into oil burner stacks. (c) Water heaters installed in manufactured homes shall be marked "for manufactured home use."
(Code 2017, § 7-204; Ord. No. 2321, § 2, 1-8-2001)