§ 7-98 — Gas piping
Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 7-98
Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/97413dd3-dfc4-4872-80fa-fecc2111b1ae
Sec. 7-98. - Gas piping.
(a) All gas piping must be black steel, galvanized pipe or corrugated stainless steel tubing and fittings. Sizing of gas lines must be adequate to deliver gas supply to all appliances connected to piping without creating a pressure drop that will prevent the appliances from operating at their intended efficiency. (b) All such pipe shall either be new or shall previously been used for no other purpose than conveying gas, and shall be clear and free from cutting burrs and defects in structure or threading and shall be thoroughly brushed and scale blown. (c) Gas piping should be run exposed wherever possible. Where gas piping is installed in concealed areas such as walls, ceilings, etc., where corrosion is no problem, welded standard pipe, corrugated stainless steel tubing and fittings or threaded fittings, all with the proper air test of ten pounds for 15 minutes, may be used. Authorized utility personnel must inspect the installation. (d) When gas piping is buried in an exterior location, either wrapped or coated pipe welded and air tested, or polyethylene pipe authorized by the gas inspector must be used. In general, no gas piping should be installed under a cement floor or slab. If this becomes necessary, wrapped black steel pipe or polyethylene pipe laid inside a gas tight duct with the duct vented to the outside must be used. The installer must furnish all necessary equipment and gauges for air testing pipelines belonging to the customer. It will be permissible to use plastic piping approved for natural gas, for outside underground lines only. (e) A shutoff valve must be provided in the pipeline ahead of each gas appliance installed, ahead of the union or appliance connector. The shutoff valve on a furnace must be installed outside the furnace cabinet where accessible. Exceptions must be approved by the gas inspector or authorized utility personnel. Approved flexible appliance connectors may be used to connect portable appliances such as ranges, dryers, etc. Flexible connectors in commercial applications will be required to be double walled or approved for commercial applications. Standard residential connectors will not be allowed in commercial applications. (f) Flexible connectors will not be allowed to pass through a wall, ceiling, floor or cabinet on movable appliances. Only one flexible connector per appliance will be allowed. (g) A drip leg shall be required on furnaces and water heaters only. Manufactured homes are exempt from this rule. (h) Copper or aluminum tubing shall not be used for gas lines or connections, except where it is part of the appliance design. (i) Pipe compound or thread tape shall be used on all fittings and of a make recommended by an approved source from its manufacturer as being approved for both LP and natural gas. (j) All gas piping carrying a gas pressure in excess of nine inches water column shall be welded and air tested. All gas piping over two inches in size shall be welded and air tested. The air test shall be no less than 150 percent the proposed working pressure, but not less than ten psig. The air test will be for 15 minutes without pressure drop. (k) Threaded pipe and fittings may be tested with an air test instead of the usual soap bubble test on all joints. The test is ten pounds for 15 minutes. Cedar Falls Utilities personnel shall witness all air tests referenced in this article and reserve the right to require a longer time for any air tests based upon pipe size, length of the pipe runs and other conditions. (l) Gas piping may be installed in concealed locations with no access in accordance with the following rule: When gas piping that is to be concealed is being installed; only elbows, tees, caps and couplings shall be used. (m) Manufactured homes may be connected to the gas meter with solid iron pipe or a Dormont type outdoor flex connector approved for manufactured home use. (n) Any natural gas piping going through brick, block or concrete walls must be sleeved with plastic pipe to protect from deterioration.
(Code 2017, § 7-201; Ord. No. 2321, § 2, 1-8-2001)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.