§ 7-102 — Space heating appliances
Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 7-102
Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/455300fa-9c43-4e41-952f-06c589b23274
Sec. 7-102. - Space heating appliances.
(a) Gas warm air furnaces, boilers and unit heaters, or any type of space heater, shall be CSAus-approved or approved by an equivalent testing laboratory. Clearance from combustible materials shall be according to manufacturer's recommendations or as required by the gas utility. (b) All heating equipment installed in a garage area shall be at least 18 inches from floor level to the burner. (c) Minimum sheet metal clearance for gas fired hot air furnaces shall be as follows, or, if this is not possible, the furnace shall be satisfactorily insulated with fireproof material: (1) Plenums on forced air furnaces with a maximum high limit setting up to 250 degrees Fahrenheit shall have a clearance of two inches from combustible material and a one-inch clearance on heat runs three feet out from the plenum. (2) Gravity furnaces where a limit higher than 250 degrees Fahrenheit is maintained, shall have adequate clearance from combustible material or be so insulated that they will be considered by an authorized gas inspector to be safe. (3) All gas-fired appliances requiring natural venting must have a draft diverter properly designed to the manufacturer's specifications. (d) Where a space heater, furnace, conversion burner or any other gas fired appliance is installed in a confined area such as a utility room or similar area, an adequate supply of combustion air must be supplied from other than the living quarters area. An outside air opening one inch larger than the combined venting area of connected equipment will be deemed adequate. (e) Any house built or remodeled after 1973 must have adequate combustion and dilution air to provide for the proper, safe operation of the natural gas furnace. Fresh air taken from outside or from a ventilated attic shall be installed, preferably into the cold air return, by the furnace installer. (f) No circulating air supply inlet for blower type warm air furnaces shall be located where there is a possibility of reversing the venting, picking up fumes, objectionable odors or flammable vapors. (g) Where exhaust fans are installed in a building that can cause the gas vents to reverse, downdraft or spill when the gas appliance is burning, the appliance must be shielded or protected or an induced draft fan must be installed so that it will function properly or more outside air must be introduced. (h) All furnaces shall be provided with an approved electrical disconnect located within reach of the furnace.
(Code 2017, § 7-205; Ord. No. 2321, § 2, 1-8-2001)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.