Sec. 7-105. - Chimneys.
(a) For heating equipment, flue liners must be used where total gas burning input is more than 50,000 or less than 350,000 Btu's per hour. (b) Installation of new furnaces that no longer use the chimney going up through the house and leave only the water heater in the chimney must have a properly sized chimney to accommodate the water heater only, even if this requires a smaller liner to be installed in the existing chimney. (c) The flue pipe should extend through the chimney wall to the inner face of the liner, but not beyond, and should be firmly cemented to masonry. The flue pipe should be sealed into the chimney liner or attached to the type B vent by use of a tee or elbow. (d) Flue connections from two or more appliances should not enter opposing or adjacent sides of the chimney or type B vent at the same level. Flue pipes must never be connected into a fireplace chimney flue.
(Code 2017, § 7-208; Ord. No. 2321, § 2, 1-8-2001)