§ 24.05.130 — Installation of Gas Piping
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.05.130
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/6ec374c3-395b-4dc7-8113-5ba46e327ee0
24.05.130 Installation of Gas Piping.
(a) Joints. Joints in the piping system, unless welded, shall be threaded joints having approved standard threads or flared joints. Threaded joints shall be made with approved pipe joint material, insoluble in fuel gas and applied to the male threads only. Welded joints in a gas-supply system shall be made by a certified pipeline welder. See Section 24.05.020. (b) Location. Gas piping shall not be installed in or on the ground under any building or structure and exposed gas piping shall be kept at least six inches above grade or structure. Concealed unprotected gas piping may be installed above grade in approved recesses or channels. EXCEPTION: When necessary due to structural conditions, approved type gas piping may be installed in other locations, when permission has first been obtained from the Administrative Authority. (c) Drip Pipes. When water vapor is present in the fuel gas served, accessible drip pipes shall be provided at points where condensation will collect. (d) Corrosion and Covering Protection. Ferrous gas piping installed under ground in exterior locations shall be protected from corrosion by approved coatings or wrapping materials applied in an approved manner. Horizontal metallic piping shall have at least twelve inches of earth cover or equivalent protection. Plastic gas piping shall have at least eighteen inches of earth cover or equivalent protection. Risers, including prefabricated risers inserted with plastic pipes, shall be metallic and shall be protected in an approved manner to a point at least six inches above grade. When a riser connects to plastic pipe underground the horizontal metallic portion underground shall be at least thirty inches in length before connecting to the plastic service pipe. An approved transition fitting or adaptor shall be used where the plastic joins the metallic riser. Gas pipe protective coatings shall be approved types, machine applied conforming to recognized standards. Field wrapping shall provide equivalent protection and is restricted to those short sections and fittings necessarily stripped for threading or welding. Zinc coatings (galvanizing) shall not be deemed adequate protection for piping below ground. Ferrous metals exposed in exterior locations shall be protected from corrosion in a manner satisfactory to the Administrative Authority. (e) Corrosion Isolation. Underground ferrous gas piping shall be electrically isolated from the rest of the gas system with listed or approved isolation fittings installed a minimum of six inches above grade. (f) Support and Fill. Gas piping shall be adequately supported by metal straps or hooks at intervals not to exceed those intervals as set out in Table No. 1 at the end of this chapter. Gas piping installed below grade shall be effectively supported at all points on undisturbed or well-compacted soil or sand. (g) Building Shutoff. Gas piping supplying more than one building on a premises shall be equipped with separate shutoff valves to each building, so arranged that the gas supply can be turned on or off to an individual or separate building. The shutoff valve shall be located outside the building it supplies and shall be readily accessible. Buildings accessory to single-family residences are exempt from the requirements of this subsection. (h) Unions. Groundjoint unions may be used at exposed fixture, appliance, or equipment connections and in exposed exterior locations immediately on the discharge side of a building shutoff valve. Heavy-duty, flanged-type unions may be used. Bushings shall not be in concealed locations. (i) Interjections. When air, oxygen or other special supplementary gas under pressure is introduced with the regularly supplied gas, either directly into the gas piping system or at burners, a device approved by the Administrative Authority shall be installed to prevent backflow of the supplemental gas into the gas-piping system. The device shall be located between the source of the supplemental gas and meter and shall be on the gas line leading to the appliance using the special gas. This device may be either a spring-loaded or diaphragmtype check valve and shall be capable of withstanding the pressure imposed on it. When liquefied petroleum or other standby gas is interconnected with the regular gas-piping system, an approved three-way two-port valve or other adequate safeguard acceptable to the Administrative Authority shall be installed to prevent backflow into either supply system. (j) Valves. Valves used in connection with gas piping shall be approved types, AGA approved and stamped. (k) Barbecue or Fireplace Outlets. Gas outlets in a barbecue or fireplace shall be controlled by an approved operating valve located in the same room and outside the fireplace but not more than four feet from the outlets. If piping on the discharge side of the control valve is standard weight brass, galvanized steel, or black iron pipe, the piping may be embedded in or surrounded by not less than two inches of concrete or masonry. (l) Shutoff Valve. An accessible shutoff valve of a type set forth in Subsection (j) of this section shall be installed in the fuel-supply piping outside of each appliance and ahead of the union connection thereto, and in addition to any valve on the appliance. Shutoff valves shall be within three feet of the appliance. Shutoff valves may be located immediately adjacent to and inside or under an appliance when placed in an accessible and protected location and when such appliance may be removed without removal of the valve. Shutoff valves may be accessibly located inside wall heaters and wall furnaces listed for recessed installation where necessary maintenance can be performed without removal of the shutoff valve. (m) Tracer for Nonmetallic Buried Piping. A No. 18 copper tracer wire or other approved conductor shall be installed with and attached to underground nonmetallic gas piping and shall terminate above grade at each end. (n) Directional Changes. Changes in direction of gas piping shall be made by use of appropriate fittings, except that polyethylene gas piping and tubing may be bent to a radius not less than twenty times the nominal diameter of the pipe or tube.
(Ord. 16542 §13; January 24, 1994)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.