24.05.190 Required Gas Piping Size.

(a) General. When the maximum demand does not exceed 250 cubic feet per hour and the maximum length of piping between the meter and the most distant outlet does not exceed 250 feet, the size of each section and each outlet of any system of gas piping shall be determined by using Table No. 4 or 4A as set out at the end of this chapter as applicable. Other systems within the range of Table No. 4 or 4A, as applicable, may be sized from those tables or by the methods set forth in Subsection (b) of this section. To determine the size of each section of pipe in a system within the range of Table No. 4 or 4A, as applicable, proceed as follows: (1) Measure the length of the pipe from the gas meter location to the most remote outlet on the system. (2) In Table No. 4 or 4A, as applicable, select the column showing that distance, or the next longer distance, if the table does not give the exact length. (3) Starting at the most remote outlet, find in the vertical column just selected, the gas demand for that outlet. If the exact figure of demand is not shown, choose the next larger figure below in the column. (4) Opposite this demand figure, in the first column at the left in Table No. 4, will be found the correct size of pipe. (5) Using this same vertical column, proceed in a similar manner for each section of pipe serving this outlet. For each section of pipe, determine the total gas demand supplied by that section. Where gas piping sections serve both heating and cooling equipment and the installation prevents both units from operating simultaneously, only the larger of the two demand loads need be used in sizing these sections. (6) Size each section of branch piping not previously sized by measuring the distance from the gas meter location to the most remote outlet in that branch and follow the procedures of steps (2), (3), (4) and (5) above. (Note: Size branch piping in the order of their distance from the meter location, beginning with the most distant outlet not previously sized.) (b) High Demands and Long Runs. For conditions other than those covered by Subsection (a) of this section, such as longer runs or greater gas demands, the size of each gas-piping system shall be determined by standard engineering methods acceptable to the Administrative Authority and each system shall be so designed that the total pressure drop between the meter or other point of supply and any outlet when full demand is being supplied to all outlets will not exceed 0.5-inch water column pressure. (c) Other Systems. When the gas pressure is higher than 14 inches or lower than six inches water column, or when diversity demand factors are used, the design, pipe, sizing, materials, location and use of such systems shall be approved by the Administrative Authority. Piping systems designed for pressures higher than the serving gas supplier's standard delivery pressure shall have prior verification from the gas supplier of the availability of the design pressure. Systems using undiluted liquefied petroleum gas may be sized using Table No. 5 set out at the end of this chapter for eleven inches water column and in accordance with the provisions of Subsections (a) and (b).

(Ord. 16542 §19; January 24, 1994)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.