24.05.150 Liquefied Petroleum Gas Facilities and Piping.

In addition to the requirements of this chapter for gas piping, the facilities and piping for use with liquefied petroleum gas shall meet the following requirements: Liquefied petroleum gas facilities shall conform to approved standards. Liquefied petroleum gas facilities and their locations shall be approved by the Administrative Authority and shall conform to state and city fire-prevention regulations. When liquefied petroleum gas facilities serve more than one customer through separate piping systems, each system shall be identified in a manner satisfactory to the Administrative Authority. Liquefied petroleum gas facilities shall be so placed as to be readily accessible for inspection, reading, testing and shutting off the gas supply. Service piping and main supply shutoff valves shall be outside of the building. Main supply valves shall be of approved type and readily accessible. Gas piping inlets shall be located with respect to the proposed liquefied petroleum gas facility location in accordance with the requirements of this section. Liquefied petroleum gas facilities shall not be located in a pit or basement, under show windows or interior stairways, in engine, boiler, heater or electric meter rooms. When not prohibited by another regulation, approved liquefied petroleum gas metering devices may be located in the open under exterior stairways. Pipejoint compounds used on threaded connections shall be insoluble in liquefied petroleum gas. Valves and appurtenances used in liquefied petroleum gas systems shall be designed and approved for use with liquefied petroleum gas. Discharge from relief valves shall be into open air and shall be at least five feet measured horizontally from an opening into a building which is below the discharge.

(Ord. 16542 §15; January 24, 1994)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.