§ 41:17-8-2: Requirements for Trash Racks, Overflow Grates and Escape Provisions.
1. A trash rack is a device designed to catch trash and debris and prevent the clogging of outlet structures. Trash racks shall be installed at the intake to the outlet from the stormwater management basin to ensure proper functioning of the basin outlets in accordance with the following: a. The trash rack shall have parallel bars, with no greater than six inch spacing between the bars. b. The trash rack shall be designed so as not to adversely affect the hydraulic performance of the outlet pipe or structure. c. The average velocity of flow through a clean trash rack is not to exceed 2.5 feet per second under the full range of stage and discharge. Velocity is to be computed on the basis of the net area of opening through the rack. d. The trash rack shall be constructed and installed to be rigid, durable, and corrosion resistant, and shall be designed to withstand a perpendicular live loading of 300 pounds per square feet. 2. An overflow grate is designed to prevent obstruction of the overflow structure. If an outlet structure has an overflow grate, such grate shall meet the following requirements: a. The overflow grate shall be secured to the outlet structure but removable for emergencies and maintenance; b. The overflow grate spacing shall be no less than two inches across the smallest dimension; c. The overflow grate shall be constructed and installed to be rigid, durable, and corrosion resistant, and shall be designed to withstand a perpendicular live loading of 300 pounds per square feet. 3. For purposes of this Section, escape provisions mean the permanent installation of ladders, steps, rungs, or other features that provide easily accessible means of egress from stormwater management basins. Stormwater management basins shall include escape provisions as follows: a. If a stormwater management basin has an outlet structure, escape provisions shall be incorporated in or on the structure. With the prior approval of the reviewing agency identified in subsection 41:17-8-3 a freestanding outlet structure may be exempted from this requirement. b. Safety ledges shall be constructed on the slopes of all new stormwater management basins having a permanent pool of water deeper than 2.5 feet. Such safety ledges shall be comprised of two steps. Each step shall be four feet to six feet in width. One step shall be located approximately 2.5 feet below the permanent water surface, and the second step shall be located one to 1.5 feet above the permanent water surface. See subsection 41:17-8-3 for an illustration of safety ledges in a stormwater management basin. c. In new stormwater management basins, the maximum interior slope for an earthen dam, embankment, or berm shall not be steeper than three horizontal to one vertical.
[Added 9-5-2024 by Ord. No. 6PSF-E , 09-05-2024 ]
Ask a question about Newark law
Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.