Section 14.05.0100 - Chapter 1—Administration.
Chapter 1 of the 2024 Edition of the International Fire Code is amended to read as follows: SECTION 101 - GENERAL 101.1 Title. These regulations shall be known as the Fire Code of the City of Sparks Fire Department, hereinafter referred to as "this code". 102.3: Change of use or occupancy A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the International Existing Building Code. Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code, provided that the new or proposed use or occupancy is less hazardous, based on life and fire risk, than the existing use or occupancy. The fire code official shall require the applicant to complete the provisions noted in NFPA 25, 2023 Edition, Chapter 4, Section 4.1.6, Changes in Occupancy, Use, Process, or Materials, and Figure E.1, Fire Sprinkler Hazard Evaluation. 102.7 Referenced codes and standards. The codes and standards referenced in the International Fire Code, 2024 Edition, Chapter 80, shall apply. "International Fuel Gas Code" is deleted and replaced with "NFPA Standard 54/ANSI Z223.1 National Fuel Gas Code, 2024 Edition, or the most current version adopted by the Board for the Regulation of Liquified Petroleum Gas in NAC 590.610." SECTION 103 - CODE COMPLIANCE AGENCY 103.3.1 Sparks Fire Department's Staff The Community Risk Reduction Division will be staffed in accordance with the policies of the City of Sparks and shall have the powers of police officers to carry out the provisions of this code. SECTION 104 - DUTIES AND POWERS OF THE FIRE CODE OFFICIAL 104.10.2 Physical evidence. If it appears that a fire is of accidental, natural, or incendiary origin, the Fire Official conducting the investigation is authorized to take immediate charge of all physical evidence relating to the cause of the fire. SECTION 105 - PERMITS 105.5.22 Hazardous materials. An operational permit is required to store, transport on site, dispense, use or handle, hazardous materials in excess of the amounts listed in Table 105.5.22. When a permit is required to be obtained for hazardous materials, the Nevada Combined Agency Hazardous Material Facility Report must be completed and the appropriate fees paid. 105.5.58 Fire-fighter Air Replenishment Systems. An operational permit is required to store, transport on site, dispense, use or handle, hazardous materials in excess of the amounts listed in Table 105.5.22. When a permit is required to be obtained for hazardous materials, the Nevada Combined Agency Hazardous Material Facility Report must be completed and the appropriate fees paid. 105.5.59 Emergency responder radio coverage system. An operational permit is required for the operation and maintenance of an emergency radio coverage system and related equipment, as specified in Section 510. SECTION 106 - CONSTRUCTION DOCUMENTS 106.2.1: Information on Construction documents. Construction documents shall be drawn to scale on suitable material. Documents in a digital format are allowed to be submitted where approved by the fire code official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and "show in detail" that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations as determined by the fire code official. "Show in detail" means that plan notes, specifications, or comments referencing codes and standards alone are not sufficient. Each reference must include the applicable code section, and the designer or contractor must provide enough detail for the plan reviewer to verify compliance with all provisions of the adopted codes and standards. SECTION 108 - FEES [A] 108.4 Work commencing before permit issuance. A person who commences any work, activity or operation regulated by this code before obtaining the necessary permits shall be subject to pay four-times the estimated permit fees for such work. SECTION 109 - INSPECTIONS [A] 109.2.1.1 Afterhours Inspections. Upon availability of a fire inspector, the holder of the permit or their duly authorized agent can request for an after-hour inspection at a minimum of three-hours to perform such inspection. The requester shall contact the permit center for payment prior to such inspection can be Scheduled. SECTION 113 - VIOLATIONS 113.4 Violation penalties. Persons who violate a provision of this code or fail to comply with any of the requirements thereof, or who erect, install, alter, repair, or do work in violation of the approved construction documents or directives of the fire code official, or of a permit or certificate used under the provisions of this code, shall be guilty of a misdemeanor. Each day that a violation continues after due notice has been served shall be deemed a separate offense. SECTION 114 - STOP WORK ORDER 114.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be guilty of a misdemeanor. SECTION 115 - UNSAFE STRUCTURES OR EQUIPMENT 115.8 Structure unfit for human occupancy. A structure is unfit for human occupancy whenever the city official finds that such structure is unsafe, unlawful or, because of the degree to which the structure is in disrepair or lacks maintenance, is insanitary, vermin or rat infested, contains filth and contamination, or lacks ventilation, illumination, sanitary or heating facilities or other essential equipment required by this code, or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. Persons so notified shall immediately leave the structure or premises and shall not enter or re-enter until authorized to do so by the city official or the city official in charge of the incident. 115.9 Dangerous structure or premises. A building or structure, used or intended to be used for dwelling purposes, because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangement, inadequate light, ventilation, mechanical or plumbing system, or otherwise, is determined by the city official to be unsanitary, unfit for human habitation or in such a condition that is likely to cause sickness or disease. Persons so notified shall immediately leave the structure or premises and shall not enter or re-enter until authorized to do so by the city official or the city official in charge of the incident.
(Ord. 2670, § 3, 04/27/2026; Ord. 2569, § 3, Amended, 11/13/2018; Ord. 2266, Add, 02/28/2005; Ord. 2407, Amended, 08/11/2008; Ord. 2471, § 56, Amended, 2/11/2013; Ord. No. 2479, § 2, 09/09/2013)
Ask a question about Sparks law
Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.