Section 14.05.0900 - Chapter 9—Fire protection and life safety systems.
901.11 Unwanted Fire Alarms. Unwanted fire alarms are a violation of this code. Then a fire alarm system is required by this code, it shall be the responsibility of the property owner or owner's authorized agent to maintain the system and properly educate occupants, tenants, and/or employees in accepted behavioral practices that will minimize or eliminate false and/or nuisance alarms. This includes nuisance activations in response to predictable environmental stimuli such as but not limited to cooking fumes, smoking, and construction activities. Where unwanted alarms become repetitive, the fire code official is authorized to charge fees or issue administrative citations to the property owner in accordance with the fee schedule or administrative code as established by the applicable governing authority. 903.2 Where Required. Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12. All other buildings not noted in Section 508.1 that is required to have installed an automatic fire sprinkler system or systems, shall have a fire control room with the minimum dimensions of 7 feet by 5 feet with an approved exterior door subject to the approval by the fire department. A horn/strobe shall be installed above the exterior door. Signage shall be added to the indicate "Fire Control Room". This required signage shall be reflective and at a minimum 18-inches in height. Exception: R-3s are exempt from this requirement and spaces or areas in telecommunications buildings used exclusively for telecommunications equipment, associated electrical power distribution equipment, batteries not required to have an automatic sprinkler system by Section 1207 for energy storage systems and standby engines, provided that those spaces or areas are equipped throughout with an automatic smoke detection system in accordance with Section 907.2 and are separated from the remainder of the building by not less than 1-hour fire barriers constructed in accordance with Section 707 of the International Building Code or not less than 2-hour horizontal assemblies constructed in accordance with Section 711 of the International Building Code, or both. 903.2.1.2 Group A-2. An automatic sprinkler system shall be provided for Group A-2 occupancies and throughout all the stories from the A-2 occupancy to and including the levels of exit discharge serving that occupancy where one of the follow conditions exists: 1. The fire area exceeds 5,000 square feet (464 m 2 ) 2. The fire area has an occupant load of 100 or more. 3. The fire area is located on the floor other than a level of exit discharge serving such occupancies. Occupancies containing a casino, regardless of occupancy classification, must be designed and built with a sprinkler system classified as an Ordinary Hazard Group 2. Add Table 903.2.1 to Section 903.2, to read as follows: Table 903.2.1 a Required Automatic Sprinklers by Fire Area, Response Time and Height for Buildings Designed and Constructed with the International Building Code Including A, B, E, F, H, I, M, S, and U Occupancies. Sprinklers are required when any one of the listed conditions are met, or when otherwise required by this Code. Fire Authority | Fire Area b In square feet (sf) | Height In stories | Response Time In minutes (min) Sparks Fire Department | ≥5,000 | >2 | >6 This table is in addition to any other automatic sprinkler requirements in this code. a. Fire areas may be separated according to IBC 707.3.10. b. Any addition or remodel that increases the fire area will be included in the calculation for the total square footage. Add Table 903.2.2 to read as follows: Table 903.2.2 a Required Automatic Sprinklers by Fire Area, Response Time and Height for Structures Designed and Constructed with the International Residential Code Sprinklers are required when any one of the listed conditions are met, or when otherwise required by this Code. Fire Authority | Fire Area b In square feet (sf) | Height In stories | Response Time In minutes (min) Sparks Fire Department | ≥5,000 | - | >6 a. This table is in addition to any other automatic sprinkler requirements in this code. b. Any addition or remodel that increases the fire area will be included in the calculation for the total square footage. The use of fire walls and fire barriers shall not be allowed to be used to reduce the size of the fire areas. c. A one-time increase in the fire area is permitted provided said increase is <50% of the structure's existing permitted fire area square footage. 903.2.3 Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows where one of the following exists: 1. Throughout all Group E fire areas greater than 12,000 5,000 square feet (1,115 464 m 2 ) in area. 2. The Group E fire area is located on a floor other than a level of exit discharge serving such occupancies. Exception: In buildings where every classroom has not fewer than one exterior exit door at ground level, an automatic sprinkler system is not required in any area below the lowest level of exit discharge serving that area. 3. Group E fire area has an occupant load of 300 or more. 4. Daycare facilities where there is occupancy from 12:00 am - 6:00 am and care for 7 or more children. 903.2.11.7. Protection of Available Storage Height. In Group S-1 and all other storage areas the fire sprinkler system shall be designed to protect storage up to the maximum available storage height. The minimum sprinkler density shall be equivalent to that required for a Class IV commodity pursuant to NFPA 13. 903.3.1.3 NFPA 13D Sprinkler Systems. Automatic sprinkler systems installed in one and two-family dwellings; Group R-3; Group R-4, Condition 1; and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D. The following features shall be included in all NFPA 13D system installation. a. Design with passage purge. b. Have installed a spare box with the appropriate wrenches for each sprinkler type c. A minimum of one of each sprinkler type shall be provided in the required spare box. 903.4.1 Sprinkler System Supervision and Alarms. Valves controlling the water supply for automatic sprinkler systems, pumps, tanks, water levels and temperatures, critical are pressures and water-flow switches on all sprinkler systems shall be electrically supervised by a listed fire alarm control unit. Exceptions: 1. Automatic sprinkler systems protecting one- and two-family dwellings that have not been converted to an R-4 as defined by 203.9.4. 2. Limited area systems in accordance with Section 903.3.8. 3. Automatic sprinkler systems installed in accordance with NFPA 13R where a common supply main is used to supply both domestic water and the automatic sprinkler system, and a separate shutoff valve for the automatic sprinkler system is not supervised. 4. Jocky pump control valves that are sealed or locked in open position. 5. Control valves to commercial kitchen hoods, painted spray booths or dip tanks that are sealed or locked in the open position. This exception will not apply to any of the above-mentioned control valves if they are located in a building equipped with any fire alarm or protection system that is required to be monitored by a central station fire alarm company. 6. Valves controlling the fuel supply to fire pump engines that are sealed or locked in the open position. 7. Trim valves to pressure switches in dry, pre-action, and deluge sprinkler systems that are sealed or locked in the open position. 903.4.3 Alarms (Shall be replaced with the following) 903.4.3 Alarms. Approved alarm notification appliances shall be connected to each automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Approved alarm notification appliances shall be provided on the exterior of the building and within each tenant space on the interior of the building and in an approved location. The exterior appliance shall be a horn/strobe device. When residential (single family dwelling) automatic sprinkler systems are provided, water flow activation shall provide occupant notification at all occupied levels and sleeping units, with minimum audible notification level of 75 dba sound pressure at pillow height. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. Section 903.4.4 Floor control valves Amend Section 903.4.4 to read: 903.4.4 Floor control valves. Approved supervised indicating control valves shall be provided at the point of connection to the riser and/or standpipe on each floor in multi-story facilities. All valves shall have a minimum clear space of 12-inches from any obstructions, including walls and other equipment. 905.4 Location of Class I standpipe hose connections. Class I standpipe hose connections shall be provided in all the following locations: 1. In every required interior exit stairway or exterior exit stairway, a hose connection shall be provided for each story above and below grade plane. Hose connections shall be located at the main floor and each intermediate landing, in accordance with NFPA 14, unless otherwise approved by the fire code official. 906.2 General Requirements. Portable fire extinguishers shall be selected, installed, and maintained in accordance with this section and NFPA 10. The internal components of carbon, dioxide, wet chemical, halogenated agent, aqueous film-forming foam (AFFF) and film-forming fluoroprotein (FFFP) portable fire extinguishers shall be examined in accordance with NFPA Standard 10, 2022 edition, Table 7.3.3.1. The internal components of all other portable fire extinguishers shall be examined annually. Exemptions: 1. Travel distance to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 Occupancies. 2. Thirty-day inspections shall not be required, and maintenance shall be allowed to be once every three years annually for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1. Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2 Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3 The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4 Electronic monitoring devices and supervisory circuits shall be tested every three years annually when extinguisher maintenance is performed. 2.5 A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3. In Group I-3, portable fire extinguishers shall be permitted to be located at staff locations. 907- FIRE ALARM - Sparks FD amendments for shell building 907.1 General. This section covers the application, installation, performance and maintenance of fire alarm systems and their components in new and existing buildings and structures. The requirements of Section 907.2 are applicable to new buildings and structures. The requirements of Section 907.9 are applicable to existing buildings and structures. 907.1.1 Construction documents. Construction documents for fire alarm systems shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code; the International Building Code; and relevant laws, ordinances, rules and regulations, as determined by the fire code official. 907.1.2 Fire alarm shop drawings. Shop drawings for fire alarm systems shall be prepared in accordance with NFPA 72 and submitted for review and approval prior to system installation. 907.1.3 Equipment. Systems and components shall be listed and approved for the purpose for which they are installed. 907.2 Where required—new buildings and structures. An approved fire alarm system installed in accordance with the provisions of this code, Sparks Fire Department ordinance, and NFPA 72 shall be provided in new buildings and structures in accordance with Sections 907.2.1 through 907.2.23 and provide occupant notification in accordance with Section 907.5, unless other requirements are provided by another section of this code. For all proposed shell commercial buildings with undetermined use and/or number of units shall be provided with a fire alarm system with a minimum of two, three amps NAC circuits. All commercial tenant improvement work shall have their fire alarm system within their suite upgraded to meet the provisions of this code adoption. All R-Occupancies with a fire alarm system, shall meet the maximin distances outlined in NFPA 72.8.1 with regards to a smoke detector shall be within 21 feet from all exterior doors of bedrooms. If multiple detectors are with 21 feet from each other, they shall be cross-zone activation designed. This purpose is to avoid any unwarranted activation. Not fewer than one manual fire alarm box shall be provided in an approved location to initiate a fire alarm signal for fire alarm systems employing automatic fire detectors or waterflow detection devices. Where other sections of this code allow elimination of fire alarm boxes due to sprinklers, a single fire alarm box shall be installed. Exceptions: 1. The manual fire alarm box is not required for fire alarm systems dedicated to elevator recall control and supervisory service. 2. The manual fire alarm box is not required for Group R-2 occupancies unless required by the fire code official to provide a means for fire watch personnel to initiate an alarm during a sprinkler system impairment event. Where provided, the manual fire alarm box shall not be located in an area that is open to the public. 907.2.1.2.1 Fire alarm systems in assembly use type occupancy. All entertainment systems shall shut-off upon alarm activation of the building fire alarm system. 907.2.9.4 Automatic Smoke Detection System in Group R-4. An automatic smoke detection system that activates the occupant notification system in accordance with Section 907.5 shall be installed in corridors, waiting areas open to corridors and habitable spaces other than sleeping units and kitchens. Exceptions: 1. Smoke detection in habitable spaces is not required where the facility is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. 2. An automatic smoke detection system is not required in buildings that do not have interior corridors serving sleeping units and where each sleeping unit has a means of egress door opening directly to an exit or to an exterior exit access that leads directly to an exit. 907.2.11.8 Alternative to Single- and Multiple-Station Smoke Alarms. Fire alarms in place of single and multiple-station smoke alarms may be replaced by an NFPA 72 Household compliant fire alarm system. Plans shall be submitted to the local fire authority and permits obtained prior to installation. All fire alarm installation contractors shall be required to be licensed by both the Nevada State Contractors Board and Nevada State Fire Marshal (F License). 907.5.2.1.1 Average Sound Pressure. The audible alarm notification appliances shall provide a sound pressure level of 15 decibels (dBA) above the average ambient sound level or 5 dBA above the maximum sound level having a duration of at lease 60 seconds, whichever is greater, in every occupiable space within the building. The minimum sound pressure level shall be 90 dBA in mechanical equipment rooms and 80 dBA in all other occupancies. 907.5.2.3 Visible Alarms. Visible alarm notification appliances shall be provided in accordance with Sections 907.5.2.3.1 through 907.5.2.3.3. Exceptions: 1. Visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system is installed. 2. Visible alarm notification appliances shall not be required in exits as defined in Chapter 2. 3. Visible alarm notification appliances shall not be required in elevator cars. 4. Visual alarm notification appliances are not required in critical care areas of Group I-2, Condition 2 occupancies that are in compliance with Section 907.2.6, Exception 2. 907.10 Smoke alarm maintenance. Smoke alarms shall be tested and maintained in accordance with the manufacturer's instructions. Smoke alarms shall be replaced when they fail to respond to operability tests, or when they exceed 10 years from the date of manufacture, unless an earlier replacement is specified in the manufacturer's published instructions. The provisions of this section apply when any work that requires a permit is conducted on a new or existing building or structure. 913.4 Valve Supervision. Where provided, the fire pump suction, discharge and bypass valves, and isolation valves on the backflow prevention device or assembly shall be supervised open by one of the following methods. 1. Central-station, proprietary or remote-station signaling service. 2. Local signaling service that will cause the sounding of an audible signal at a constant attended location. 915.1.1 Where Required. Carbon monoxide detection shall be provided in Group I-1, I-2, I-4, and R's, including, without limitation, Residential Group R-3 occupancies used for transient occupancy of less than 30 days, and in classrooms in Group E occupancies in the locations specified in Section 915.2 where any of the conditions in Sections 915.1.2 through 915.1.6 exist. 1. In buildings that contain a CO source. 2. In buildings that contain or are supplied by a CO-producing forced-air furnace. 3. In buildings with attached private garages. 4. In buildings that have a CO-producing vehicle that is used within the building.
(Ord. 2670, Added, 04/27/2026)
Ask a question about Sparks law
Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.