For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14.05.0300 — General requirements

Code of Ordinances of the City of Sparks, Nevada (Codified through Ordinance No. 2676, adopted July 27, 2026 (Supp. No. 25)) · Sparks Code of Ordinances § 14.05.0300

Corpus is an independent public-information project, not the official City of Sparks website. Stable reference: corpuslaw.us/code/3f944ceb-f335-40c0-9dd7-73e4940e377f

Section 14.05.0300 - General requirements.

CHAPTER 3 GENERAL REQUIREMENTS 307.6 Outdoor fireplaces, fire pits and decorative appliances. Outdoor fireplaces, fire pits and decorative appliances fueled by LP-gas or natural gas, used in assembly occupancies for the public display shall be equipped with an automatic timer shut off valve with a maximum time limit of 3 hours. The timing valve shall be installed a minimum of 2' from the appliance or as approved by the fire code official. 308.1.6.3 Sky lanterns. Sky lanterns are prohibited. 314.4 Vehicles. Liquid-fueled or gaseous-fueled vehicles, aircraft, boats or other motorcraft shall not be located indoors except as follows: 1. The engine starting system is made inoperable or ignition batteries are disconnected. 2. Fuel in fuel tanks does not exceed any of the following: 2.1. Class I, II and III liquid fuel does not exceed one-quarter tank or 5 gallons (19 L), whichever is less. 2.2. LP gas does not exceed one-quarter tank or 6.6 gallons (25 L), whichever is less. 2.3. CNG does not exceed one-quarter tank or 630 cubic feet (17.8 m3), whichever is less. 2.4. Hydrogen does not exceed one-quarter tank or 2,000 cubic feet (57 m3), whichever is less. 3. Electric battery vehicles shall be charged to only 50% capacity. SECTION 323 - BATTERY RECYCLING AND BATTERY RECYCLING STORAGE FACILITIES 323.1 General. Battery Recycling and Battery Recycling Storage Facilities shall be operated and maintained in accordance with this section and Section 320 where applicable. 323.1.1 Technical Opinion & Report. A technical opinion and report complying with 104.2.2, shall be prepared to evaluate the fire risks associated with all new battery recycling facilities and battery recycling storage facilities. The report shall be provided to the fire code official for review and approval. 323.1.1.1 Items required, to be addressed in the Technical Report: 1. Battery sorting specifications and procedures. 2. Protection from hazards involving flying debris during fire incidents igniting adjacent storage areas, buildings, or other exposures, where applicable. 3. Protection of areas and equipment where battery recycling occurs, including fire detection and suppression, and protection. 4. An evaluation of the suitability of the processing equipment used. 5. Combustible dust hazards, including cathode and anode powders; and processes that involve or generate dust or powders, as applicable. 6. Firefighting access and water supply. 7. Separation distances between materials, incompatible materials, and water reactive materials, as applicable. 8. Intake and inspection procedures and segregation of high-risk batteries. 9. Storage configuration of batteries or cells, including high piled storage requirements where storage exceeded 6 feet (1.82 m) in height. 10. Ventilation requirements 11. Other items as required by the fire code official. 12. Description of method by which the state of charge will be verified and maintained at or below 30%. 323.1.2 Emergency Procedures & Response Plan. Battery Recycling and Battery Recycling Storage Facilities shall develop and maintain emergency procedures and a written safety and emergency response plan for each facility. The plan shall include any emergency conditions unique to that facility including the batteries that it may process or store. The plan shall be submitted to the fire code official for review and shall be approved. The safety and emergency response plan shall include (but is not limited to) the following: 1. Procedures for employee training related to anticipated emergency scenarios, including fire events, battery off-gassing, thermal runaway, and post-event mitigation. 2. Spill prevention and control measures. 3. Procedures for coordination with emergency responders, including access to hazard communication information, including Safety Data Sheets. 4. A facility map detailing the locations of emergency equipment and access routes. 5. Isolation procedures for batteries exhibiting signs of thermal runaway. 323.1.2.1 Abatement. The emergency response plan shall include procedures for the abatement of hazardous conditions following fire events or battery damage. The abatement plan shall be approved by the fire code official. 323.2 Battery Recycling Facilities 323.2.1 Fire Protection 323.2.1.1 Fire Suppression Systems. Battery recycling facilities shall be protected by an automatic sprinkler system in accordance with Section 903.3. 323.2.1.2 Fire Alarm and Detection Systems. A listed or approved automatic aspirated smoke detection system, radiant energy fire detection system complying with Section 907.2 shall be installed to protect battery recycling and battery recycling storage areas. Alarm signals from detection systems shall be transmitted to a central station and shall be in accordance with NFPA 72. 323.2.2 Explosion Control 323.2.2.1 Explosion Control Requirements. Where required by the technical report, explosion control shall be in accordance with Section 911. 323.2.3 Ventilation. Indoor recycling areas shall be provided with a mechanical exhaust ventilation system. 323.2.4 Sorting. Sorting of batteries shall be in accordance with the technical opinion report and is subject to AHJ approval. 323.2.5 Weather Protection. Where outdoor battery recycling areas, and such areas that are enclosed, such areas shall be considered indoor recycling facilities. A technical opinion report, complying with 325.1.1 shall be provided to address the fire resistance rating of the structure, fire detection, fire suppression, and explosion control within the weather protected area. 323.3 Battery Recycling Storage Facilities 323.3.1 Storage Arrangement Plan. A storage plan, which illustrates the storage arrangement, including the location and dimensions of aisleways, storage piles, storage racks, and any fire protection and detection equipment, and its proximity to the storage, shall be provided to and approved by the fire code official. 323.3.2 Fire Extinguishers. Fire extinguishing equipment suitable for all types of batteries present shall be provided throughout battery recycling loading and unloading areas in accordance with NFPA 10, travel distance to reach fire-extinguishing equipment shall not exceed 75 feet (22.9 m). 323.3.3 Indoor Recycling Storage: 323.3.3.1 Construction Requirements. Where indoor storage areas are located in a building with other uses, battery storage areas shall be separated from the remainder of the building by 2-hour rated fire barriers or horizontal assemblies. Fire barriers shall be constructed in accordance with Section 707 of the International Building Code , and horizontal assemblies shall be constructed in accordance with Section 711 of the International Building Code. 323.3.4 Outdoor Recycling Storage: 323.3.5 Packaging. Batteries for recycling are to be stored in weather appropriate noncombustible containers, or containers packaged in accordance with DOTn shipping regulations, and shall be deemed acceptable by the fire code official. Under no circumstances will cardboard packaging be used for outdoor storage areas. 323.3.5.1 Damaged Packaging. Batteries shall not be stored in damaged packaging, where the damage compromises the container. If packaging is visibly damaged the batteries shall be promptly repackaged in containers complying with 323.3.5.

(Ord. 2670, Added, 04/27/2026)

Ask a question about Sparks law

Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.