§ 14.05.1000 — Means of egress
Code of Ordinances of the City of Sparks, Nevada (Codified through Ordinance No. 2676, adopted July 27, 2026 (Supp. No. 25)) · Sparks Code of Ordinances § 14.05.1000
Corpus is an independent public-information project, not the official City of Sparks website. Stable reference: corpuslaw.us/code/debe1a3e-f142-4890-8d04-d4180c5cf4e4
Section 14.05.1000 - Means of egress.
[BE] 1009.3.2 Stairway width. Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails. [BE] 1011.2: Width and capacity. The required capacity of stairways shall be determined as specified in Section 1005.1, but the minimum width shall be not less than 44 inches (1119 mm). The minimum width for stairways that serve as part of the accessible means of egress shall comply with Section 1009.3 Exceptions: 1. Spiral stairways as provided for in Section 1011.10. 2. Where an incline platform lift or stairway chairlift is installed on stairways serving occupancies in Group R-3, or within dwelling units in occupancies in Group R-2, a clear passage width nor less than 20 inches (508 mm) shall be provided. Where the seat and platform can be folded when not in use, the distance shall be measured from the folded position. [BE] 1011.12 Stairway to roof. In buildings four or more stories above grade plane , one stairway shall extend to the roof surface, unless the roof has a slope steeper than 4 units vertical in 12 units horizontal (33-percent slope). 1023.9.1 Signage Requirements. Stairway identification signs shall comply with all of the following requirements: 1. The signs shall be a minimum size of 18 inches (457 mm) by 12 inches (305 mm). 2. The letters designating the identification of the interior exit stairway and ramp shall be not less than 1 ½ inches (38 mm) in height. 3. The number designating the floor level shall be not less than 5 inches (127 mm) in height and located in the center of the sign. 4. Other lettering and numbers shall be not less than 1 inch (25 mm) in height. 5. Characters and their background shall have a non-glare finish. Characters shall contrast with their background, with either light characters on a dark background or dark characters on a light background. 6. Where signs required by Section 1023.9 are installed in the interior exit stairways and ramps of buildings subject to Section 1025, the signs shall be made of the same materials as required by Section 1025.4. 7. The background color of the sign shall be green if roof access is available from the signed stairway. The background color of the sign shall be red if roof access is not available from the signed stairway.
(Ord. 2670, Added, 04/27/2026)
Ask a question about Sparks law
Corpus searches the Sparks sections it holds and shows the ones that match, with their citations. Free, no sign-in.