§ 1508.06 — Fire hydrant spacing
Codified Ordinances of the City of Delaware, Ohio (Codified through Ordinance No. 26-37, enacted September 14, 2026. (Supp. No. 28)) · Delaware Codified Ordinances § 1508.06
Corpus is an independent public-information project, not the official City of Delaware website. Stable reference: corpuslaw.us/code/b42e6c0c-3aa5-4c39-b8f8-94f988921847
1508.06. - Fire hydrant spacing.
(a) General. (1) The distance from fire hydrants to buildings, or parts thereof, shall be the distance as measured by hose laid from fire apparatus within a paved surface. Fire hydrants shall be located not more than 8 feet from the edge of the road to be considered as accessible for a building, unless authorized by the Fire Chief. (2) The placement and location of fire hydrants shall be accomplished as specified by the Fire Official. (3) A minimum of two public fire hydrants must be within 500 feet of every building or part thereof; the public hydrants shall be accessed by means of separate driveway or roadway openings into the site, unless otherwise approved by the Fire Official. (4) If the spacing requirements, as stated in subsection (3) hereof, cannot be accomplished, on-site private fire hydrants shall be provided, by the property owner, using the following spacing requirements: a minimum of one fire hydrant shall be within 300 feet of every building or part thereof, with a minimum of one additional hydrant within 500 feet of every building or part thereof. (5) The maximum distance between adjacent fire hydrants is 300 feet. (6) A fire hydrant shall be provided to within 150 feet of the terminus of dead-end streets. (7) Fire hydrants shall be placed at least forty feet from buildings protected whenever possible. (8) Fire hydrants shall be located two feet behind the back of the curb line, or eight feet from the edge of the paved area on noncurbed roadways; unless otherwise approved by the Fire Official. (9) Fire hydrants shall be located and/or protected from possible mechanical damage. The means of protection shall be arranged in such a manner which will not interfere with the connection to, operation of, and the maintenance of hydrants. Bollards used to protect hydrants shall be at least three feet from the hydrant on all sides. (10) Fire hydrants shall be located so as not to be obstructed by parking spaces, dumpsters, signs, mailboxes, utility poles, bushes, and any other structures and materials.
(Ord. 22-55. Passed 6-13-22)
Ask a question about Delaware law
Corpus searches the Delaware sections it holds and shows the ones that match, with their citations. Free, no sign-in.