§ 350-18 — Water supply and fire hydrants
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 350-18
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/7bdc4522-ebc0-4d9e-962e-ede5a0706167
§ 350-18: Water supply and fire hydrants.
A. General requirements. (1) The developer must install a water distribution system that complies with city construction standards and specifications for materials and workmanship. The system must be designed to furnish an adequate supply of water to each lot with adequate main sizes and fire hydrant locations to meet the requirements of the Insurance Services Office and City standards for a protected area. (2) A domestic water supply extension must be provided in accordance with the latest standards of AWWA, DEP Public Water Supply Manual, Part II (Chapter 8) and City construction standards and specifications for materials and workmanship. Prior to final acceptance of any new public or private water line extension, service, or repair (having a diameter or more than two inches and in excess or one full length of pipe) lines must be adequately flushed, hydrostatically tested and properly disinfected, per AWWA C-600 and C-651, respectively. (3) Distribution systems and appurtenances must be designed and constructed to maintain normal operating pressures of not less than 25 psig nor more than 125 psig at the main, except during periods of peak seasonal loads, when the pressures at the time of hourly maximum demand may not be less than 20 psig nor more than 150 psig. B. Fire hydrants and valves. (1) In neighborhood zones, fire hydrants must be placed at each intersection, with intermediate hydrants required so that spacing between hydrants does not exceed 500 feet. (2) When placing a private underground utility service or line within an adjoining public right-of-way, which exceeds the length of a standard lateral, the developer must obtain a license agreement or utility easement from the City. The developer must prepare and submit all necessary sketches and easement plats for the proposed line. (3) Each developed lot/property must be provided with a water meter and backflow prevention device per the International Building Code (IBC). Water meters will be furnished and installed by the City. C. Individual water supply systems. If public water facilities are not available and individual on-lot well systems are proposed, such wells must comply with recommended standards of the Pennsylvania Department of Conservation and Natural Resources (PA DCNR). D. Tapping fee. Each developed lot/property is subject to a water tapping fee (system capacity fee). Any increase in density or change of use requires an updated tapping fee.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.