§ 350-9 — Streets
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 350-9
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/81d5d3fb-34c0-4433-b3fd-b96f4783981a
§ 350-9: Streets.
A. General requirements. (1) Streets. (a) The location and width of all streets must conform to City ordinances, block plans and plans of record. (b) When unopened (stub-out) streets exist abutting a proposed land development or subdivision, the applicant must make application to the City to vacate the portion of the street that abuts their property unless an exception is granted by the City Engineer. (2) Grading and improvements plan. Materials and construction standards for streets, curbs, gutters, storm and sanitary sewers and sidewalks must conform to City standards, and construction and installation of facilities must conform to City specifications and are subject to inspection by the City Engineer. (3) Topography and arrangement. (a) Streets must be logically related to topography so as to produce reasonable grades. All streets must be arranged so as to obtain as many building sites as possible at, or above, the grades of the streets. Grades of streets must conform as closely as possible to the original topography. A combination of steep grades and curves shall be avoided. (b) The proposed street system must extend existing or recorded streets at the same width or wider as deemed necessary by the City, but in no case at less than the required minimum width. (c) All thoroughfares must be properly related to special traffic generators such as industries, business districts, schools, churches, and shopping centers to population densities; and to the pattern of existing and proposed land uses. (d) New half, or partial, streets are prohibited except when essential to reasonable development of a tract, and when, in addition, satisfactory assurance for dedication of the remaining part of the street is provided. (e) Whenever a proposed development borders on existing half or partial street, the remaining portion of the street must be plotted within the proposed development. (f) When a development abuts an existing street of improper width or alignment, the City may require the dedication of land within the subject development sufficient to widen the street or correct the alignment. (g) When, in the opinion of the City Engineer, it is desirable to provide for street access to adjoining property, street stubs must be extended by dedication to the boundary of such property. (h) In business or industrial developments, the streets and other accessways must be planned in connection with the grouping of buildings, location of rail facilities, and the provision of alleys, truck loading and maneuvering areas, and walks and parking areas so as to minimize conflict of movement between the various types of traffic, including pedestrian and bicycle. (4) Blocks. In general, intersection streets determine block length. The size and pattern of blocks must be designed in compliance with the following: (a) The length, width, and shape of blocks must be determined with due regard to the provision of adequate sites for buildings of the type proposed, existing patterns, zoning requirements, topography, and the requirements for safe and convenient vehicular, bicycle, and pedestrian circulation. (b) When practicable, blocks along arterial and collector streets must be at least 1,000 feet in length. Blocks along other streets may not exceed 1,000 feet in length nor be less than 500 feet in length unless an exception is granted by the City Engineer. In approving exceptions, special consideration must be given to the requirements of satisfactory fire protection and whether the modification reduces impervious area or impacts to natural resources. (c) Pedestrian crosswalks may be required to facilitate pedestrian circulation and give access to community facilities. Such crosswalks must conform to all applicable City standards. (d) Blocks in commercial and industrial areas may vary from the elements or design detailed above if the City finds necessary for the protective use, including adequate provision for off-street parking and loading areas as well as for traffic circulation and parking for employees and customers. (5) Street names. Street names may not duplicate or closely approximate, phonetically, the names of existing streets in the City, except that streets which are in obvious alignment with existing streets must generally bear the name of the existing street. (6) Street regulatory signs. Street signs are to be placed within the development, the type and location of which are to be approved by the Traffic Control Superintendent. (7) Street lights. Street lights must be provided in accordance with design and specification standards promulgated by the Pennsylvania Power and Light Company (P.P. & L.). (8) Reserve strips. Reserve strips are not permitted adjacent to a proposed street in such a manner as to deny access from adjacent property to such street. B. Design standards. (1) General. In order to provide for streets of suitable location, width and improvement to accommodate prospective traffic and afford satisfactory access to police, firefighting, snow removal, sanitation, and road maintenance equipment, and to coordinate streets so as to compose a convenient system and avoid undue hardships to adjoining properties, the following design standards for roads apply except when such standards are waived at the discretion of the City Engineer. (a) Street width and grade. [1] Street right-of-way and cartway width must comply with the regulations of Table 132-1, and street grades, in general, may not exceed the standards established in Table 132-1, with due allowance for reasonable vertical curves. [2] Additional right-of-way and cartway widths may be required by the City Engineer for the purposes of promoting the public safety and convenience or to provide parking in commercial and industrial developments. [3] Streets at a grade of 10% may not exceed 300 feet in length. [4] Minimum grade on any street may not be less than 1.0%. Table 132-1. Street Widths and Grades Classification | Min. Street Width(ft.) | Travel Lanes | Max. Grade(%) Right-Of-Way Width | Cartway Width | No. | Width (ft.) Arterial | 80 | 48 | 4 | 12 | 5 Collector | 60 | 36 | 2 | 10 | 10 Local | 50 | 34 | 2 | 10 | 10 Service | 33 | 24 | 2 | 12 | 10 Alley, public | 24 | 16 | 2 | 10 | 10 Alley, private | 16 | 16 | 2 | 8 | 10 Street | 24 | 24 | 2 | 12 | 10 (b) Street alignment. The horizontal and vertical alignment on all streets shall be as follows: [1] Horizontal curves. The minimum radius at the center line of the street and the super-elevation design when applicable for horizontal curves shall be as follows: Table 132-2. Horizontal Curves Classification | Superelevation(mph) | Radius(ft.) Arterial | 45 | 575 Collector | 35 | 325 Local | — | 250 [2] Vertical curves. At all changes in street grades when the algebraic difference exceeds 1% vertical curves must be provided to permit the following minimum sight distances: Table 132-3. Vertical Curves Classification | Distance(ft.) Arterial | 600 Collector | 300 Local | 200 [3] Sight distance. The following minimum sight distances must be provided with respect to both horizontal and vertical curves: Table 132-4. Sight Distance Classification | Distance(ft.) Arterial | 350 Collector | 275 Local | 200 (c) Street intersections. Intersections must be designed to meet the following: [1] Streets must intersect at an angle of 90°, or as nearly as possible at right angles. The angle of intersection is measured at the intersection of intersecting street center lines. [2] Intersections involving the junction of more than four streets are prohibited. [3] Street curb intersections or roadway intersections must be rounded with curves having the minimum radius indicated in Table 132-5. Table 132-5. Curb Radius Intersecting Street | Min. Curb Radius(ft.) Arterial with Collector or Local | 35 Collector with Local | 12 Local with Local | 8 Local/Service with Service | 6 Table Note: The radii shown above may be increased to suit field conditions if deemed necessary by the City Engineer. Intersections occurring at angles other than 90 degrees must be rounded with a curb having a radius length approved by the City Engineer. [4] Intersections with arterial or collector streets may be not less than 1,000 feet apart, measured from centerline to centerline along the centerline of the arterial or collector street. Local streets intersecting with collector or service streets must be at least 300 feet apart. [5] Streets entering opposite sides of another street must be laid out either directly opposite each other or with a minimum offset of 150 feet between their centerlines. [6] Intersections must be approached on all sides by a straight leveling area, the grade of which may not exceed 2% within 10 feet from the intersecting curblines or 5% within 50 feet from the intersection of street centerlines. Vertical curves must then be used to connect the intersecting grades. [7] Clear sight triangles must be provided at all street intersections. Within such triangles, no vision obstructing object is permitted in excess of 30 inches in height above the elevation of the intersecting streets. Such triangles must be established for a distance of at least 75 feet from the point of intersection of the centerlines of intersecting streets except when a greater distance is required by PennDOT standards. [8] The control of grades, curvature, and obstructions is required to ensure adequate sight distance for safe and efficient vehicular operations. Consideration for sufficient stopping, passing, and intersection sight distances is required. Design standards for the noted sight distance must be in accordance with PennDOT and/or AASHTO standards. [9] Minimum required tangential distances between reverse curves are 500 feet for arterial streets, 350 feet for collector streets, and 100 feet for local streets. The tangent distance between the curve at a right angle intersection and a street curve must be at least 30 feet. (d) Cul-de-sac streets. Dead-end streets must be designed and constructed to comply with the following: [1] Dead-end streets are prohibited, unless designed as a cul-de-sac or other city-approved geometry designed for access exclusively to adjoining properties. [2] Any street dead-ended for access to an adjoining tract or because of authorized stage development must provided with a temporary, all-weather turnaround, within the subdivision, and the use of such turnaround must be guaranteed to the public until such time as the street is extended. [3] Streets designed and approved as permanent cul-de-sacs may not exceed 500 feet in length. [4] The closed end of all permanent and temporary cul-de-sac streets must have a minimum radius to curb line of 48 feet, and the turnaround must be fully paved except that a center island consisting of low-growing vegetation or a stormwater BMP may be approved in residential areas where such island is designed to not interfere with fire protection. Adequate space for snow storage must be provided, as determined by the Department of Public Works. [5] The centerline grade on a cul-de-sac street may not exceed 10%, and the grade of the diameter of the turnaround may not exceed 5%. [6] Alternative turnaround designs may be approved by the City Engineer. (e) Service streets. Except when other adequate provision is made for off-street loading and parking consistent with the use proposed, service streets are required in mixed-use and industrial zones, Such streets must have a minimum right-of-way width of 33 feet and a minimum paved width of 24 feet. (f) Alleys. Alleys must be designed and constructed to comply with the following: [1] Alleys in residential developments must have a minimum paved width of 16 feet. [2] Dead-end alleys are prohibited. However, the City Engineer may grant exceptions when suitable turnaround provisions are provided. [3] Alley intersections and sharp changes in alignment must be avoided. Corners must be rounded or cut back sufficiently to permit safe vehicular circulation. C. Street construction. Streets must be constructed in accordance with standard details and dimensions of the City Engineering Department's Standards and Specifications. (1) The roadbed subgrade must be prepared to the established roadbed subgrade elevation and compacted to not less than 95% of the ASTM D1557 Modified Proctor Maximum Dry Density. (2) Subgrade drains must be placed along proposed roadways when directed by the City Engineer to drain wet/seepage areas. (3) During roadway construction, the developer must provide maintenance and protection of traffic in compliance with PennDOT standards. (4) Longitudinal road grades must be at least 1%. D. Drainage. All streets must be designed to provide for the discharge of surface water away from their centerline. The slope of the crown on proposed streets must comply with all applicable City standards. E. Street lights. (1) When required, the owner must install, at their own expense, street lights providing a minimum illuminance level of 1.0 foot-candles (10.8 lux), in accordance with a plan prepared by the owner's engineer and approved by the Planning Commission. (2) The design of light standards must be approved by the City Engineer before installation. (3) Provisions must be made to energize street lights when 25% of the dwellings within a subdivision or land development are constructed. The owner is responsible for all utility costs involved in lighting the streets until such time that the streets are accepted by the City as public streets. F. Crossovers. Crossovers must comply with the requirements outlined in the City's standard crossover details.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
