§ 660-20 — Storefront building
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-20
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/37e0c261-c40e-4ed2-aed1-a589b51981b0
§ 660-20: Storefront building.
A. Description and intent. With a variety of available scales depending on the zone, the storefront building type is intended for use in the downtown, along corridors, and at neighborhood nodes, accommodating shopping, services, and eating establishments in a building with uses mixed vertically. Oriented to the street with narrow or no side setbacks, this building type is highly accessible to the pedestrian. Ground story storefront glass, entrances along the sidewalk, and windows in upper stories facing the street make these buildings interesting and inviting to pedestrians. Parking, where provided, is located in the rear yard. B. Illustrative images. The images shown in Figure 660-19(3) are intended to illustrate the general character of the building type. The buildings and sites in each image may not fulfill all of the building type regulations. C. Building regulations. The following tables and illustrations regulate this specific building type. See § 660-18 for general regulations for all building types. See Article 14 for definitions and measuring table regulations. Link | Subsection § 660-20D | Building Siting § 660-20E | Parking and Accessory Structures § 660-20F | Number and Location of Dwelling Units § 660-20G | Height § 660-20H | Roofs § 660-20I | Front and Side-Street Facades § 660-20J | Supplemental Regulations [image] [image] [image] [image] D. Building siting. Figure 660-20(1) Storefront Building Siting [image] Building Siting. [See Figure 660-20(1).] Zones MX-D | MX-C | MX-N | MX-S | Additional/References Multiple Principal Buildings | Not allowed | Not allowed | Not allowed | Allowed | See § 660-18C for multiple buildings. 1 | Lot Width | 18 ft. min. | 18 ft. min. | 18 ft. min.50 ft. max. | 50 ft. min. Lot Frontage | A or B street. See § 660-18J for front street designation regulations. 2 | Front Streetwall | 90% min. | 75% min. | 75% min. | 65% min. | See § 660-131F for measuring. See front streetwall allowances for courtyard or plaza per § 660-20J(1) 3 | Front Build-to Zone | 0 ft. min.5 ft. max. | 0 ft. min.10 ft. max. | 0 ft. min.20 ft. max. | 5 ft. min.15 ft. max. | Minimum streetscape area required per § 660-18L.Double-frontage lots addressed per § 660-18J(5).See § 660-131G for measuring.See § 660-78 for required rear and side buffers. 4 | Side-Street Build-to Zone | 0 ft. min.15 ft. max. | 0 ft. min.15 ft. max. | 0 ft. min.15 ft. max. | 0 ft. min.15 ft. max. 5 | Side Setback | 0 ft. min. | 0 ft. min. | 0 ft. min. | 0 ft. min. If any side setback is provided, at least 5 ft. is required. 6 | Rear Setback | 0 ft. min. 0 ft. min. at improved alley or C street; 20 ft. min. abutting another lot 7 | Building Coverage | No limit | No limit | No limit | 70% max. | See § 660-131I for measuring building coverage. E. Parking and accessory structures. Figure 660-20(2) Storefront Building Parking Siting [image] Parking and Accessory Structures. [See Figure 660-20(2).] Zones MX-D | MX-C | MX-N | MX-S | Additional/References 8 | Parking and Driveway Access | Driveway access is allowed per § 660-18K. | One driveway access is allowed per 120 ft. of any street frontage | See Article 9 for parking. See § 660-18I for loading. 9 | Garage Setback within Building Vehicular Door Location | 20 ft. min. behind front facade above any basement Rear facade only; if the rear facade is not practicable, the side-street facade may be approved, except along Hamilton Street in MX-D. | See § 660-131J for garage door setback. 10 | Surface Parking Location | Rear yard | Rear yard | Rear yard | Rear, side yard | See § 660-77 for frontage buffer on C streets. Front and Side-Street Setback | No closer to lot line than principal building Side & Rear Setback | 3 ft. min.; 0 ft. min. at improved alley | 3 ft. min. 11 | Accessory structure Location | Rear yard | Rear yard | Rear yard | Rear yard | See Article 6 for accessory structures. Side-Street Setback | No closer to lot line than principal building Side and Rear Setback | 5 ft. min. | 5 ft. min. | 5 ft. min. | 5 ft. min. KEY ACCESSORY STRUCTURES | See Article 6 for accessory structures and uses. Outbuildings | • | • | • | • | KEY: Drive-Through Facilities | — | — | — | • | • | = | Allowed Fuel Pumps | — | — | — | • | ○ | = | Requires Special Exception Outdoor Storage | — | — | — | | — | = | Not Allowed Parking Structure | • | • | — | • F. Number and location of dwelling units. Number and Location of Dwelling units. [Refer to § 660-131L.] Zones MX-D | MX-C | MX-N | MX-S | Additional/References Principal Dwelling Units | No limit | No limit | Up to 6 units | No limit | See Article 5 for allowed uses. Accessory Dwelling Units | — | — | — | — G. Height. Figure 660-20(3) Storefront Building Height and Roofs [image] Height. [See Figure 660-20(3).] Zones MX-D | MX-C | MX-N | MX-S | Additional/References 12 | Height | Minimum | 3 stories | 2 stories | 2 stories | 2 stories Maximum | 14 stories | 3 stories | 3 stories | 3 stories 13 | Additional Stories for Affordable Housing on mixed-use corridors | — | +2 stories per § 660-20J(2) | — | +2 stories per § 660-20J(2) | Mixed-Use Corridors defined in § 660-144.See § 660-20J(4) for required setbacks at N zones. Additional stories for affordable housing in other locations | — | +2 stories with special exception approval per § 660-20J(2) | — | +2 stories with special exception approval per § 660-20J(2) Additional height allowed by Floor-Area Ratio | See § 660-20J(3). | — | — | — 14 | Ground story height | 12 ft. min.18 ft. max. | 10 ft. min.15 ft. max. | 10 ft. min.15 ft. max. | 12 ft. min.14 ft. max. | Measured floor-to-floor. See § 660-131.M for measuring height and allowances for taller spaces. 9 ft. min. with min. 18" stoop 15 | Upper story height | 9 ft. min.14 ft. max. | 9 ft. min.11 ft. max. | 9 ft. min.11 ft. max. | 9 ft. min.14 ft. max. H. Roofs. Roofs. [See Figure 660-20(3).] Zones MX-D | MX-C | MX-N | MX-S | Additional/References 16 | Allowed roof types | Flat, Parapet | Flat, Parapet, Pitched | Flat, Parapet, Pitched | Flat, Parapet, Pitched | See § 660-61 for roof types and towers Tower | Allowed | Allowed | Allowed | Allowed I. Front and side-street facades. Figure 660-20(4) Storefront Building Facades [image] Front and Side-Street Facades. [See Figure 660-20(4).] Zones MX-D | MX-C | MX-N | MX-S | Additional/References 17 | Ground story transparency on front facades | 70% min. | 60% min., except 15% for existing residential building fronting on N 7th Street | 45% min. | 70% min. | See § 660-131N for measuring transparency.Measured per story, includes any half stories, visible basement, or towers with full height stories. Measured between 2 ft. and 9 ft. from sidewalk grade No bay nor 20-ft.-wide section of any story may be without transparency Ground story transparency must extend min. 30 ft. around the corner down any side-street facades 18 | Transparency: side-street facades and upper stories on front facade | 20% min. | 15% min. | 15% min. | 20% min. No bay nor 20-ft.-wide section of any story may be without transparency 19 | Building entrances | One principal entrance per every 45 feet of front facade | See § 660-131O for measuring building entrance location. 20 | Allowed entrance types | Storefront | Storefront, Stoop | Storefront, Stoop | Storefront | See § 660-63 for entrance types. 21 | Ground-floor elevation | | Within 30 in. of sidewalk elevation 22 | Horizontal divisions with shadow lines | Within 3 ft. of the top of ground story | Within 3 ft. of the top of any story between the basement and 3rd story | Horizontal shadow lines to run a min. 80% of length of facade. 23 | Vertical Divisions with Shadow Lines | One per every 45 ft. of ground story front facade | One per every 30 ft. of ground story front facade | See § 660-150 for definition of shadow lines. J. Supplemental storefront building regulations. (1) Front streetwall variation. Either a courtyard or an outdoor seating/dining area may count towards the streetwall requirement, provided the following regulations are met: (a) Courtyard. The courtyard must have a minimum of 30 feet in width and a minimum of 20 feet in depth, surrounded on 3 sides by occupied building facade. [1] The courtyard may count towards front streetwall when abutting the build-to zone. [2] One side of the courtyard may be defined by a landscape wall constructed of an allowed facade material. [3] Parking is not allowed in courtyards. [4] Courtyard facades must be treated as front facades per facade regulations for the building type and any design regulations in Article 7. [5] The courtyard must include special paving materials and patterns, and landscape materials such as trees in grates or planters and/or landscape beds. [6] Temporary or permanent seating is required. Temporary seating must be available or in place between May 15 and September 15. (b) Outdoor seating or dining plaza. A front or side-street build-to zone may be expanded up to 20 feet from the lot line for a maximum of 20% of the front street facade or 100% of the side-street facade to allow for a permanent outdoor seating plaza or outdoor dining area. For example, a build-to zone of between zero and five feet could be expanded to zero and 25 feet. [1] The seating/dining areas must be coordinated with the streetscape. Special paving materials and patterns, landscape materials such as trees in grates or planters and/or landscape beds must be included. [2] Temporary or permanent seating is required. Temporary seating must be available or in place between May 15 and September 15. (2) Additional stories for affordable housing. Where additional stories are allowed for affordable housing per § 660-20G, the following applies: (a) Affordable housing. The project must meet the definition of affordable housing per § 660-36A(3)(d) and any supplemental use regulations associated with affordable housing. (b) Mixed-use corridors. Except within an historic district, buildings on lots abutting one of the mixed-use corridors (per § 660-144) may include up to two additional stories for affordable housing on top of the allowed three stories for a total of up to five stories. See § 660-20J(4) for required setback at N zones. (c) Other locations. Except within an historic district, buildings on lots that do not abut one of the mixed-use corridors (per § 660-144) may request special exception approval to include up to two additional stories for affordable housing on top of the allowed height of three stories for a total of up to five stories. See § 660-20J(4) for required setback at N zones. (3) Floor area ratio (FAR) in Downtown Zone. In MX-D, additional height is allowed above the maximum height in stories as follows: (a) On lots less than 80 feet in width, no additional floor area is allowed above the allowed maximum height in stories. (b) On lots 80 feet or more in width, heights may be increased up to a total allowed floor-area-ratio for the building of no more than 24. (c) See § 660-67 for high-rise design standards. (4) Setback at N zones. Any allowed "additional story" per § 660-20J(2) must be set back in the rear from any adjacent N-zoned lot line a minimum of 40 feet, including any C street or improved alley within the setback area. For example, if the C street between the subject lot and adjacent N-zoned lot is 25 feet in width and the building is setback from the C street 15 feet, no additional story setback is required. See Figure 660-20(5). Figure 660-20(5) Required Setback Additional Height Across From N Zone [image]
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
