§ 660-25 — Urban rowhouse
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-25
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/d48300a5-5ea2-4f46-9500-ed377c4bffa7
§ 660-25: Urban rowhouse.
A. Description and intent. Urban rowhouses are vertical units that may share side walls with one or two other units on separate abutting lots. Each unit is oriented to an A or B street, with an entrance from a stoop directly off the sidewalk or street. Parking is located in the rear yard and any garage access is from a rear facade. B. Illustrative images. The images shown in Figure 660-25(1) are intended to illustrate the general character of the building type. The buildings and sites in each image may not fulfill all of the building type regulations. C. Building regulations. The following tables and illustrations regulate this specific building type and apply to each rowhouse. See § 660-18 for general regulations for all building types. See Article 14 for definitions and measuring table regulations. Link | Subsection § 660-25D | Building Siting § 660-25E | Parking and Accessory Structures § 660-25F | Number and Location of Dwelling Units § 660-25G | Height § 660-25H | Roofs § 660-25I | Front and Side-Street Facades § 660-25J | Supplemental Regulations [image] [image] [image] [image] D. Building siting. Figure 660-25(2) Urban Rowhouse Siting [image] Building Siting. [See Figure 660-25(2).] Zones GX-N, N1 | Additional/References Multiple Principal Buildings | Not allowed 1 | Lot Width: Interior UnitEnd UnitLot Size | 16 ft. min.18 ft. min.1,500 s.f. min. Lot Frontage | A or B street, or two C streets (one at the front and one at the rear). See § 660-18J for front street designation regulations. 2 | Front Streetwall | 25 ft. max. width per rowhouse | Measured in build-to zone along any street frontage per § 660-131F. 3 | Front Build-to Zone | 0 ft. min.8 ft. max | See § 660-131G for measuring and front-yard averaging.Minimum streetscape area required per § 660-18L. Front-yard averaging applies 4 | Side-Street Build-to Zone | 0 ft. min.20 ft. max. 5 | Side Setback | 0 ft; if any setback provided, at least 4 ft. required. 6 | Rear Setback | 35 ft. min.; 15 ft. min. for lots less than 100 ft. deep without detached outbuilding or garage 7 | Rear Yard Landscape Area | 15 ft. min. depth, 150 s.f. min. area. 8 | Building Coverage | 70% max. | See § 660-131I for measuring building coverage. E. Parking and accessory structures. Figure 660-25(3) Urban Rowhouse Parking Siting [image] Parking and Accessory Structures. [See Figure 660-25(3).] Zones GX-N, N1 | Additional/References 9 | Parking and Driveway Access | Driveway access is allowed per § 660-18K. | See Article 9 for parking. Attached Garage Setback Allowed Garage Door Location (facade) | Attached garage not allowed— 10 | Surface Parking and Accessory Structure Location | Rear yard | See Article 6 for accessory structures. 11 | Street-Side Setback | No closer to lot line than principal building 12 | Side SetbackRear Setback | 5 ft. min. total both sides3 ft. min.; 0 ft. min. at improved alley for surface parking KEY ACCESSORY STRUCTURES | KEY: Outbuildings (includes Detached Garages) | • | • | = | Allowed Drive-Through Facilities | — | ○ | = | Requires Special Exception Fuel Pumps | — | — | = | Not Allowed Outdoor Storage | — Parking Structure | — F. Number and location of dwelling units. Number and Location of Dwelling Units. (Refer to § 660-131L.) Zones GX-N, N1 | Additional/References Principal Dwelling Units | 1 in principal building | See Article 5 for allowed uses and § 660-42 for accessory dwelling unit requirements. Accessory Dwelling Units | 1 in principal building G. Height. Figure 660-25(4) Urban Rowhouse Height and Roofs [image] Height. [See Figure 660-25(4).] Zones GX-N, N1 | Additional/References 13 | Height | 1.5 stories min.2.5 stories max. with Pitched Roof or3 stories max with Flat or Parapet Roof Type | See supplemental regulations on half stories in § 660-25J.See § 660-131M for measuring height. 14 | Floor-to-Floor Height | 9.5 ft. min.11 ft. max. | Measured floor-to-floor. 15 | Height to Eaves for Pitched Roofs | 20 ft. max. | Height to eaves is measured from the first floor to the bottom of the eave.See § 660-131M for measuring height to eaves. H. Roofs. Roofs. [See Figure 660-25(4).] Zones GX-N, N1 | Additional/References 16 | Allowed Roof Types | Pitched with ridge parallel to front lot line; Parapet, Flat | See § 660-61 for roof types and towers. Tower | Not allowed I. Front and side-street facades. Figure 660-25(5) Urban Rowhouse Facades [image] Front and Side-Street Facades. [See Figure 660-25(5).] Zones GX-N, N1 | Additional/References 17 | Transparency: Front FacadesSide Facades | 15% min.10% min. | Measured per story, including any half stories, visible basement, or towers with full-floor height.See § 660-131N for measuring transparency. On the front facade, no bay nor 10-ft.-wide section of any story may be without transparency 18 | Entrance Location | Front or side-street facade 19 | Allowed Entrance Types | Stoop, Porch | See § 660-63 for entrance types. 20 | Ground-Floor Elevation | Between 12 in. and 30 in. above grade Horizontal Divisions with Shadow Lines | — | See § 660-150 for definition of shadow lines. Vertical Divisions with Shadow Lines | — J. Supplemental urban rowhouse regulations. (1) Half stories in roof. See § 660-131M(8) for definition of half story. (a) The occupiable footprint of half stories in the roof is limited to no more than 65% of the footprint of story below. (b) Dormers on half stories are limited to no more than 50% of the facade length of the story below.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
