§ 660-32 — Workshop building
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-32
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/10bb6eff-9472-48e0-9765-5ff3d51a8f99
§ 660-32: Workshop building.
A. Description and intent. The workshop building accommodates larger interior spaces primarily for production and manufacturing with a minimum level of orientation to the sidewalk and pedestrians. In more visible locations, the front of the building has transparency regulations making the building appear storied at the front. B. Illustrative images. The images shown in Figure 660-32(1) are intended to illustrate the general character of the building type. The buildings and sites in each image may not fulfill all of the building type regulations. C. Building regulations. The following tables and illustrations regulate this specific building type. See § 660-18 for general regulations for all building types. See Article 14 for definitions and measuring table regulations. Link | Subsection § 660-32D | Building Siting § 660-32E | Parking and Accessory Structures § 660-32F | Height § 660-32G | Front and Side-Street Facades § 660-32H | Supplemental Regulations [image] [image] [image] [image] D. Building siting. Figure 660-32(2) Workshop Building Siting [image] Building Siting. [See Figure 660-32(2).] Zones IX, P1, P2 | IG, IM | Additional/References Allowed per Table 660-3 | Allowed in IX; allowed in P1 and P2 zones by special exception. | Allowed | See § 660-18C for multiple buildings. Multiple Principal Buildings | Allowed | Allowed 1 | Lot Width | 40 ft. min. | 80 ft. min. Lot Frontage | A or B street. See § 660-18J for front street designation regulations. 2 | Front Streetwall | 35% min. | — | Measured in build-to zone along any front lot line per § 660-131F. 3 | Front Build-to Zone or Setback | 10 ft. min.35 ft. max. | 10 ft. min. setback— | Minimum streetscape area required per § 660-18L. 4 | Side-Street Setback | 5 ft. min. | 10 ft. min. | See § 660-131G for measuring. 5 | Side Setback | 8 ft. min. | 8 ft. min. | See § 660-78 for landscape buffer Adjacent to N Zones. Side Setback Adjacent to N Zone | 15 ft. min. | 15 ft. min. Space between Buildings | 12 ft. min. | 12 ft. min. 6 | Rear Setback | 10 ft. min. | 10 ft. min. Rear Setback Adjacent to N Zone | 30 ft. min. | 30 ft. min. 7 | Building Coverage | 85% max. | 85% max. | See § 660-131I for measuring building coverage. E. Parking and accessory structures. Figure 660-32(3) Workshop Building Parking Siting [image] Parking and Accessory Structures. [See Figure 660-32(3).] Zones IX, P1, P2 | IG, IM | Additional/References 8 | Parking and Driveway Access | 1 per 120 ft. of street frontage; or 2 on front street if no C street, improved alley, or side street abuts the property | See Article 9 for parking. 9 | Allowed Garage Door Location | Any facade | Any facade 10 | Surface Parking and Loading Location | Any yard | Any yard | See § 660-78 for landscape buffer adjacent to N zones. Front, Side-Street, Side and Rear Setback | 5 ft. min., 15 ft. min. abutting to N zone 11 | Accessory Structure Location | Rear, side yard | Rear, side yard | See Article 6 for accessory structures. Street Setback | No closer to lot line than principal building | Same as building setback Side and Rear Setback | 5 ft. min., 15 ft. min. abutting to N zone KEY ACCESSORY STRUCTURES Outbuildings | • | • | KEY: Drive-Through Facilities | — | — | • | = | Allowed Fuel Pumps | • | • | , accessory to use only | ○ | = | Requires Special Exception Outdoor Storage | • | • | — | = | Not Allowed Parking Structure | • | • F. Height. Figure 660-32(4) Workshop Building Height [image] Figure 660-32(5) Workshop Building Facades [image] Height. [See Figure 660-32(4).] Zones IX, P1, P2 | IG, IM | Additional/References 12 | Height | 50 ft. max. | 50 ft. max.;See § 660-32H for additional height on larger parcels | See § 660-131M for measuring height. G. Front and side-street facades. Front and Side-Street Facades. [Figure 660-32(5).] Zones IX, P1, P2 | IG, IM | Additional/References 13 | Transparency: Front Façade | 20% min. | — | Measured per story. See § 660-131N for measuring transparency. No bay nor 20-ft-wide section of any story may be without transparency, except garage door bays | — See § 660-131N(5) for tall story transparency requirements on tall stories over 18 ft. in height | — H. Supplemental workshop building regulations. (1) Additional height. On lots 15 acres or larger in area, the maximum height of the building may be increased through a special exception approval, provided the following: (a) Other zone setback. Any portion of the building that exceeds 50 feet in height must be set back from any other zone other than IX, IG, or IM a distance of two times the height of that portion of the building. For example, where a building has portions with heights of 75 feet and 100 feet, the portion that is 75 feet high must be set back a minimum of 150 feet from the adjacent zone and the portion that is 100 feet high must be set back 200 feet from the adjacent zone. (b) Street setback. Additionally, the portion of the building with increased height must be set back a minimum of 50 feet from any street frontage with building frontage along the street no taller than 50 feet in height.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
