For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 660-21 — Commercial center

Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-21

Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/c497d0e4-b6d2-4ff2-98f6-edd4fcac9707

§ 660-21: Commercial center.

A. Description and intent. The commercial center is a single building or collection of buildings accommodating both vehicular and pedestrian access comfortably. Some buildings must be built up to the sidewalk; however, additional buildings may be located set back from the front lot line. Vehicular uses, such as fueling stations and service stations, may be located within this building type, along with shopping centers and larger grocery stores. B. Illustrative images. The images shown in Figure 660-21(1) are intended to illustrate the general character of the building type. The buildings and sites in each image may not fulfill all of the building type regulations. C. Building regulations. The following tables and illustrations regulate this specific building type. See § 660-18 for general regulations for all building types. See Article 14 for definitions and measuring table regulations. Link | Subsection § 660-21D | Building Siting § 660-21E | Parking and Accessory Structures § 660-21F | Number and Location of Dwelling Units § 660-21G | Height § 660-21H | Roofs § 660-21I | Front and Side-Street Facades § 660-21J | Supplemental Regulations [image] [image] [image] [image] D. Building siting. Figure 660-21(2) Commercial Center Building Siting [image] Building Siting. [See Figure 660-21(2).] Zones MX-S | Additional/References Multiple Principal Buildings | Allowed | See § 660-18C for multiple buildings. 1 | Lot Width | 60 ft. min. Lot Frontage | A or B street. See § 660-18J for front street designation regulations. 2 | Front Streetwall | 65% min.;See § 660-21J for locations where reduced minimum streetwall is allowed | Courtyards, outdoor dining, side parking allowances per § 660-21J.Measured in build-to zone along any street frontage per § 660-131F. 3 | Front Build-to Zone | 10 ft. min.20 ft. max. | Minimum streetscape area required per_ § 660-18L. 4 | Side-Street Setback | 5 ft. min. | See § 660-131G for measuring. 5 | Side Setback | 5 ft. min., 10 ft. min. abutting any N zone | See § 660-78 for required rear and side buffers. 6 | Rear Setback | 5 ft. min.; 20 ft. min. abutting N zone 7 | Building Coverage | 60% max. | See § 660-131I for measuring building coverage. E. Parking and accessory structures. Figure 660-21(3) Commercial Center Parking Siting [image] Parking and Accessory Structures. [See Figure 660-21(3).] Zones MX-S | Additional/References 8 | Parking and driveway Access | One per 120 ft. of street frontage | See Article 9 for parking. 9 | Garage Setback within Building Vehicular Door Location | 20 ft. min. behind front facade above any basement Side-street, side, rear facade | See § 660-131J for garage door setback. 10 | Surface Parking Location | Rear yard, interior yard, side yard | See § 660-156 for definition of yards. Front and Side-Street Setback | 5 ft. min.; side yard parking may extend into the front yard to within up to 5 ft. from front lot line Side and Rear Setback | 5 ft. min. 11 | Accessory Structure Location | Rear yard | See Article 6 for accessory structures. Side-Street Setback | No closer to lot line than principal building Side and Rear Setback | 5 ft. min.; 15 ft. min. abutting to N zone KEY ACCESSORY STRUCTURES Outbuildings | • Drive-Through Facilities | • | KEY: Fuel Pumps | • | Allowed in rear or side yard | • | = | Allowed Outdoor Storage | ○ | ○ | = | Requires Special Exception Parking Structure | • | — | = | Not Allowed F. Number and location of dwelling units. Number and Location of Dwelling Units. (Refer to § 660-131L.) Zones MX-S | Additional/References Principal Dwelling Units | No limit | See Article 5 for allowed uses. Accessory Dwelling Units | — G. Height. Figure 660-21(4) Commercial Center Height and Roofs [image] Height. [See Figure 660-21(4).] ZONES MX-S | Additional/References 12 | Height | 1 story min.3 stories max. | See § 660-21J for additional height for large format spaces.Stories are measured floor-to-floor. See § 660-131M for measuring height and allowances for taller spaces. 13 | Ground Story Height | 10 ft. min., 15 ft. max. for multi-story building; additional height for large format spaces per § 660-21J 14 ft. min., 18 ft. max. for single-story building 14 | Upper Story Height | 9 ft. min.12 ft. max. H. Roofs. Roofs. [See Figure 660-21(4).] Zones MX-S | Additional/References 15 | Allowed Roof Types | Flat, Parapet, Pitched | See § 660-61 for roof types and towers. See § 660-21J for pitched roof on single-story building. Tower | Allowed I. Front and side-street facades. Figure 660-21(5) Commercial Center Facades [image] Front and Side-Street Facades. [See Figure 660-21(5).] Zones MX-S | Additional/References 16 | Ground Story Transparency on Front Facades | 65% min. | Ground story transparency measured between 2 ft. and 10 ft. from sidewalk grade. See § 660-131N for measuring transparency. No bay nor 20-ft.-wide section of any story may be without transparency Ground story transparency must extend a min. 30 ft. around the corner, down any side-street facades 17 | Transparency: Street Facades | 18% min. | Measured per story, includes any half stories, visible basement, or towers with full-floor height. See § 660-131N for measuring transparency. No bay nor 20-ft.-wide section of any story may be without transparency 18 | Building Entrance Location | One per every 65 feet of front facade and interior-yard parking lot front-facing facades | See § 660-131O for measuring building entrance location. 19 | Allowed Entrance Types | Storefront | See § 660-63 for entrance types. 20 | Ground-Floor Elevation | Within 24 in. of sidewalk elevation 21 | Horizontal Divisions with Shadow Lines | Within 3 ft. of the top of ground story | Horizontal shadow lines to run a min. 80% of length of facade. See § 660-150 for definition of shadow lines. 22 | Vertical Divisions with Shadow Lines | One per every 65 ft. of ground story front street facade J. Supplemental commercial center regulations. (1) Front streetwall variation. Either a courtyard or an outdoor seating/dining area may count towards the streetwall requirement, provided the following regulations are met: (a) Courtyard. The courtyard must have a minimum of 30 feet in width and a minimum of 20 feet in depth, surrounded on three sides by occupied building facade. [1] The courtyard may count towards front streetwall when abutting the build-to zone. [2] One side of the courtyard may be defined by a landscape wall. [3] Parking is not allowed in courtyards. [4] Courtyard facades must be treated as front facades per facade regulations for the building type and any design regulations in Article 7. [5] The courtyard must include special paving materials and patterns, and landscape materials such as trees in grates or planters and/or landscape beds. [6] Temporary or permanent seating is required. Temporary seating must be available or in place between May 15 and September 15. (b) Outdoor seating or dining plaza. A front or side-street build-to zone may be expanded up to 20 feet from the lot line for a maximum of 20% of the front street facade or 100% of the side-street facade to allow for a permanent outdoor seating plaza or outdoor dining area. For example, a build-to zone of between zero and five feet could be expanded to zero and 25 feet. [1] The seating/dining areas must be coordinated with the streetscape. Special paving materials and patterns, landscape materials such as trees in grates or planters and/or landscape beds must be included. [2] Temporary or permanent seating is required. Temporary seating must be available or in place between May 15 and September 15. (2) Reduced front streetwall. The minimum streetwall may be reduced under the following circumstances: (a) Street frontages. Where the front lot line is parallel to one of the following streets outside of the traditional City center, a minimum streetwall of 35% is allowed: [1] Union Boulevard, west of Jasper Street; [2] Airport Road; [3] Hamilton Boulevard west of College Drive; [4] Tilghman Street west of Cedar Crest Boulevard; [5] S 4th Street; [6] Lehigh Street south of W Tioga Street; [7] Glenwood Street SW; [8] W Emaus Avenue; [9] Industrial Avenue; and [10] 31st Street SW. (b) Fueling stations. Where fueling stations are located outside the street frontages defined in Subsection 3(2)(a), a minimum streetwall of 35% is allowed. (3) Large-format spaces. Large-format spaces have taller floor-to-floor heights, large building footprints, and few or no windows. Examples include such stores as grocery stores, department stores, warehouse retail stores, and movie theaters. Large-format spaces are allowed in a commercial center per the following: (a) A ground story up to 30 feet in height is allowed for the large format space. (b) The facade of the large format space is limited to a maximum horizontal distance along any front street of 60 feet. See Figure 660-21(6). Figure 660-21(6) Large-Format Space [image] (c) Lower scaled commercial spaces meeting the building type requirements may front the large-format space to achieve the maximum frontage and number of entrances required along the frontage. (d) Any heights over 18 feet located on the front facade or side-street facade must apply transparency regulations as if the building is two stories along those facades. (4) Pitched roof on single-story building. A pitched roof on a single-story building must have a minimum pitch of 1:5. Where the ridge is parallel to a street, dormer windows must be provided, one, minimum six feet wide, for every 30 feet of roof length. See Figure 660-21(7). Figure 660-21(7) Pitched Roof on Single Story Commercial Center [image]

Ask a question about Allentown law

Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.