§ 660-23 — Small general building
Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-23
Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/3246a910-4c0c-47c9-8ae9-bc28cb07d534
§ 660-23: Small general building.
A. Description and intent. The small general building is a basic urban building, typically housing multiple residential units, office, laboratory spaces, classrooms, services, and similar spaces. Oriented to the street with an entrance to the public sidewalk, the building often has a small front setback. The scale of the building is smaller than the general building, lower in height and limited in width. Parking is located in the rear yard. B. Illustrative images. The images shown in Figure 660-23(1) are intended to illustrate the general character of the building type. The buildings and sites in each image may not fulfill all of the building type regulations. C. Building regulations. The following tables and illustrations regulate this specific building type. See § 660-18 for general regulations for all building types. See Article 14 for definitions and measuring table regulations. Link | Subsection § 660-23D | Building Siting § 660-23E | Parking and Accessory Structures § 660-23F | Number and Location of Dwelling Units § 660-23G | Height § 660-23H | Roofs § 660-23I | Front and Side-Street Facades § 660-23J | Supplemental Regulations [image] [image] [image] [image] [image] D. Building siting. Figure 660-23(2) Small General Building Siting [image] Building Siting. [See Figure 660-23(2).] Zones GX-C, GX-N, NX | N1, N2 | N3 | Additional/References Allowed per Table 660-3 | Allowed | Allowed only with special exception approval | Allowed Multiple Principal Buildings | Not allowed | Not allowed | Allowed per § 660-23J 1 | Lot Width | 18 ft. min. | 36 ft. min. | 65 ft. min. on corner lot of A or B street; 80 ft. min. on interior lot Lot Frontage | A or B street. See § 660-18J for front street designation regulations. 2 | Front Streetwall | 65 ft. max., not including any courtyard | 50 ft. max. | 65 ft. max., not including any courtyard | Measured in build-to zone along any street frontage per § 660-131F. 3 | Front Build-to Zone | 5 ft. min.20 ft. max. | 0 ft. min.15 ft. max. | 15 ft. min.35 ft. max. | See § 660-131G for measuring and front-yard averaging. Minimum streetscape area required per § 660-18.L. — | — | Front-yard averaging applies 4 | Side-Street Build-to Zone | 5 ft. min.15 ft. max. | 0 ft. min.15 ft. max. | 7.5 ft. min.15 ft. max. 5 | Side Setback | 0 ft. min; if any provided, at least 5 ft. required | 0 ft. min; if any provided, at least 5 ft. required | 5 ft. min. 6 | Rear Setback | 5 ft. min. at improved alley or C street; 20 ft. min. abutting another lot | 15 ft. min.; 0 ft. min. on corner lot bounded by A, B, & C streets | 30 ft. min. 7 | Building Coverage | 70% max. | 70% max. | 60% max. | See § 660-131I for measuring building coverage. E. Parking and accessory structures. Figure 660-23(3) Small General Building Parking Siting [image] Parking and Accessory Structures. [See Figure 660-23(3).] Zones GX-C, GX-N, NX | N1, N2 | N3 | Additional/References 8 | Parking and Driveway Access | Driveway access is allowed per § 660-18K. | See Article 9 for parking. 9 | Attached Garage Setback Allowed Garage Door Location | 20 ft. min. behind front facadeSide-street, rear facades | See § 660-131J for garage door setback. 10 | Surface Parking Location | Rear yard; limited side yard | Rear yard | Rear yard | See § 660-131K for allowed limited side-yard parking layout. Front and Side-Street Setback | No closer to lot line than principal building Side and Rear Setback | 3 ft. min.; 0 ft. min. at improved alley | 3 ft. min. | 3 ft. min.; 0 ft. min. at improved alley 11 | Accessory Structure Location | Rear yard | Rear yard | Rear yard | See Article 6 for accessory structures. Side-Street Setback | No closer to lot line than principal building Side and Rear Setback | 5 ft. min. | 5 ft. min. | 5 ft. min. KEY ACCESSORY STRUCTURES | KEY: Outbuildings (includes Detached Garages) | • | • | • | • | = | Allowed Drive-Through Facilities | — | — | — Fuel Pumps | — | — | — | ○ | = | Requires Special Exception Outdoor Storage | — | — | — | — | = | Not Allowed Parking Structure | — | — | — F. Number and location of dwelling units. Number and Location of Dwelling Units. [Refer to § 660-131L.] Zones GX-C, GX-N, NX | N1, N2 | N3 | Additional/References Principal Dwelling Units | Up to 3 units allowed per every 18 ft. of front facade width;Up to 12 units allowed with special exception approval. | Up to 1 unit allowed per every 18 ft. of front facade width per building;Up to 6 units allowed with special exception | See Article 5 for allowed uses.See § 660-131L for measuring. Accessory Dwelling Units | Not allowed | Not allowed | Not allowed G. Height. Figure 660-23(4) Small General Building Height and Roofs [image] Height. [See Figure 660-23(4).] Zones GX-C, GX-N, NX | N1, N2 | N3 | Additional/References 12 | Height | 2 stories min.3 stories max. | 2 stories min.3.5 stories max. | 2 stories min.3 stories max. | See § 660-131M for measuring height. 13 | Story Height | 9-12 ft. | 9-11 ft. | 9-11 ft. | Measured floor-to-floor. H. Roofs. Roofs. [See Figure § 660-23(4).] Zones GX-C, GX-N, NX | N1, N2 | N3 | Additional/References 14 | Allowed Roof Types | Flat, Parapet | Flat, Parapet | Flat, Parapet, Pitched | See § 660-61 for roof types and towers. Tower | Not allowed | Not allowed | Not allowed I. Front and side-street facades. Figure 660-23(5) Small General Building Facades [image] Front and Side-Street Facades. [Figure 660-23(5).] Zones GX-C, GX-N, NX | N1, N2 | N3 | Additional/References 15 | Transparency: Front and Side-Street Facades | 20% min. | 20% min. | 20% min. | Measured per story, including any half stories, visible basement, or towers with full-floor height. See § 660-131N for measuring transparency. No bay nor 10-ft.-wide section of any story may be without transparency 16 | Building Entrance Location | Front facade | Front facade | Front facade 17 | Allowed Entrance Types | Stoop | Stoop | Stoop | See § 660-63 for entrance types. 18 | Ground-Floor Elevation | Between 0 and 30 in. above grade orbetween 30 in. and 48 in, with a visible basement | See § 660-133 for definition of visible basement. 19 | Horizontal Divisions with Shadow Lines | Minimum of one within 3 ft. of the top of any story between the basement and 1st story | Horizontal shadow lines to run a min. 80% of length of facade. Vertical Divisions with Shadow Lines | — | — | — | See § 660-150 for definition of shadow lines. J. Supplemental small general building regulations. (1) Multiple small general buildings on a lot. Multiple principal Small General buildings may be located on a lot, consistent with the following: (a) All buildings must be submitted and developed at the same time. (b) Each building must be located within the front build-to zone and must fulfill all of the requirements of the building type unless otherwise expressly stated. (c) Minimum spacing between buildings is 10 feet. (d) An alternative layout may be approved as a special exception per § 660-115.
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.
