Sec. 33-76. - Sand filters.
These minimum standards shall apply, where applicable, to either gravity or pressure sand filters. (1) Filter tanks shall be designed with a factor of safety of four (4) in relation of working pressure to ultimate strength. ..... (2) The filter bed shall consist of suitable grades of filter sand and a supporting bed of graded gravel or other porous material which shall serve to support the filter bed and distribute both filtered and backwash water uniformly. The supporting bed consisting of graded gravel or other material shall support not less than twenty (20) inches of filter media consisting of silica sand or other durable, inert material with an effective size between four-tenths (0.4) and fifty-five-hundredths (0.55) millimeters, and a uniformity coefficient and not exceeding one and three-quarters (1.75). ..... (3) The minimum freeboard to the drawoff point of backwash water shall not be less than twelve (12) inches above the normal level of the top of the filter bed. The minimum backwash rate shall be not less than twelve (12) gallons per square foot of filter bed per minute. ..... (4) Where anthracite coal or other filter media is employed, the freeboard shall be adequate to prevent the media being carried off to waste when the filter bed is backwashed at a rate adequate to carry off foreign material filtered from the water. The freeboard and the rate of backwash shall be the subject of individual design, based upon specific gravity of the media. ..... (5) The underdrain system shall be such that uniform collection of filtered water and distribution of backwash water shall be provided over the entire bed area. ..... (6) Ratio of total underdrain orifice area to total area of bed shall not be less than one-quarter (0.25) percent, nor more than four-tenths (0.40) percent. ..... (7) Orifices or interstices in the underdrain system shall be uniformly distributed over the entire filter bed area, or so designed that the flow of water through the beds shall be at uniform velocity and uniform rate over the whole area for both filtering and backwashing operations, within minimum practicable limits and those established by generally approved and accepted waterworks practice. The underdrain system design shall be one (1) which demonstrably will provide a uniform flow distributed over the entire bed area. ..... (8) The underdrain system shall be provided of material which is corrosion-resistant and enduring, wherein the orifices shall be so designed and of such material that they will maintain approximately constant area and velocity. ..... (9) Design rate for sand filters shall be three (3) gallons per minute, per square foot of bed area, at time of maximum head loss, as a minimum standard. ..... (10) The filter plant shall be provided with influent and effluent pressure gauges, illuminated backwash sight glass and air relief valves. ..... (11) The filter plant shall be provided with face piping and valving to permit the functions of filtering to pools or backwashing to waste with the battery as a whole or any unit operated singly. ..... (12) The filter plant shall be provided with means for draining all filter units and piping, so that all parts of the system may be completely drained to prevent damage from freezing. .....
(Code 1986, § 33-76)
Ask a question about Chattanooga law
Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.