§ 33-82 — Main drain spacing
Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 33-82
Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/f45c8109-10f2-4cc8-aa46-91829262ffcd
Sec. 33-82. - Main drain spacing.
(a) When the outlets to pool pump suction are installed in the pool floor near one (1) end, the spacing shall not be greater than twenty (20) feet on centers and an outlet shall be provided not more than fifteen (15) feet from each side wall. At least one (1) outlet shall be provided at the lowest point of the floor to completely drain the entire floor area. ..... (b) The outlet grate clear area shall be such that when the maximum flow of water is being pumped through the floor outlet, the velocity through the clear area of the grate shall not be greater than one and one-half (1½) feet per second. Outlet grates shall be slotted and the minimum dimension of lots shall be not more than one-half (½) inch. ..... (c) Where outlets fittings consist of parallel plates, of so-called antivortex type where the water enters the fittings from the sides, rather than through a grating facing upward, entrance velocities may be increased to six (6) feet per second. ..... (d) All pool fittings shall be of corrosion-resistant materials. .....
(Code 1986, § 33-82)
Ask a question about Chattanooga law