§ 33-89 — Coagulant feeder and pH adjustment

Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 33-89

Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/d95dab5e-6358-4dea-8c47-770a3379e25d

Sec. 33-89. - Coagulant feeder and pH adjustment.

(a) The coagulant feeder shall be an electrically powered, positive-displacement type pump to ensure full delivery of the chemical solution being fed. Feed rate shall be adjustable with the pump in operation. Each suction stroke of the pump shall be visible through a sight feed indicator. The point of application shall be on the suction side of the circulating pump. The feeder shall be capable of delivering sufficient chemical solution to treat the pool water with a dosage of not less than three (3) grains per gallon. ..... (b) (1) For adjustment for pools of more than seventy-five thousand (75,000) gallons capacity, an electrically powered, positive displacement type pump shall be used. The point of application shall be in the return line between the filters and the pool. The capacity of the feeder shall be such that the pH of the pool will be maintained as set forth in section 33-90(4). (2) For pools less than seventy-five thousand (75,000) gallons capacity other means of pH control such as pH blocks, etc., will be accepted. ..... (3) Cast-iron pot-type feeders or any feeder that depends on differential pressures are prohibited. .....

(Code 1986, § 33-89)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.