§ 33-77 — Diatomaceous earth filters
Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 33-77
Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/58bbfd87-5051-4f20-a38e-1a0b13495e81
Sec. 33-77. - Diatomaceous earth filters.
All diatomite type filters, whether of the vacuum or pressure type, shall comply in all respects with the standards of the National Sanitation Foundation covering such filters. The following requirements are applicable: (1) Sufficient filter area shall be provided to meet the design pump capacity. ..... (2) The design rate of filtration shall not be greater than the following: ..... DESIGN RATE OF FILTRATION (GPM/Sq.Ft. of effective filtering surface) Types of Filtration Systems | Rates | Type of Body Feed Pressure | 2.0 | Without continuous body feed. 2.5 | With continuous body feed. Vacuum | 1.5 | Without continuous body feed. 2.0 | With continuous body feed. (3) Where body feed is provided, the device shall be accurate (ten percent (10%)) and dependable, and shall be capable of continually feeding within a calibrated range, adjustable from two (2) to six (6) ppm, at the design capacity of the recirculation pump. ..... (4) Filter area, where fabric is used, shall be determined on the basis of effective filtering surfaces as created by the septum supports with no allowances for areas of impaired filtration, such as broad supports, folds or portions which may bridge. ..... (5) The filter and all component parts shall be of such materials, design and construction as to withstand normal continuous use without significant deformation, deterioration, corrosion or wear which could adversely affect filter operation. ..... (6) The filter shall be so designed and constructed, or provision made, to preclude the introduction of appreciable quantities of filter aid into the pool during pre-coating operations. ..... (7) The tank containing the filter elements shall be constructed of steel or other suitable material approved by the department. Pressure filters shall be designed for a minimum working pressure of fifty (50) pounds per square inch with a four (4) to one (1) safety factor. Vacuum filters shall be designed to withstand the pressure developed by the weight of the water contained therein and closed vacuum filters shall, in addition, be designed to withstand the crushing pressure developed under a vacuum of twenty-five (25) inches of mercury with a safety factor of one and one-half (1.5) in both instances. The septa or elements which support the filter aid shall be of corrosion-resistant material and shall be provided with openings, as specified in the NSF standard for diatomite type filters. The septa shall be constructed to be resistant to rupture under conditions of the maximum differential pressure between influent and effluent which can be developed by the circulating pump and of adequate strength to resist any additional stresses developed by the cleaning operation. ..... (8) Where dissimilar metals, which may set up galvanic electric currents, are used in the filters, provision shall be made to resist electrolytic corrosion. The filters shall be designed in such a manner that they may be easily disassembled with allowances made for adequate working space above and around the filters to allow the removal and replacement of any part and for proper maintenance. ..... (9) The filter plant shall be provided with such pressure, vacuum or compound gauges as are required to indicate the condition of the filter. In vacuum filter installations where the circulating pump is two (2) horsepower or higher, an adjustable high vacuum automatic shutoff shall be provided to prevent damage to the pump by cavitation. ..... (10) All filters shall be equipped for cleaning by one (1) or more of the following methods: Backwashing, airbump-assist backwashing, spray wash (meticanical or manual), or agitation. ..... (11) Provision shall be made for completely and rapidly draining the filter. ..... (12) Each filter unit shall be provided with an access opening of not less than a standard eleven (11) inch by fifteen (15) inch manhole and cover. ..... (13) Pressure filter tanks shall be supported by jack legs or other supports to give a free movement of air under each tank and to permit access for painting. ..... (14) Filter turn-over cycle shall be of a capacity to completely filter the entire pool body in not more than eight (8) hours, and preferably six (6) hours. .....
(Code 1986, § 33-77)
Ask a question about Chattanooga law
Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.