§ 33-81 — Mechanical pool fittings
Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 33-81
Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/c14e8622-dd34-42cb-9fa4-e400327d2a3a
Sec. 33-81. - Mechanical pool fittings.
(a) Where overflow gutters are installed, outlet spacing shall not be greater than fifteen (15) feet on centers. ..... (b) Overflow gutter branch lines from each drain fitting shall not be less than two (2) inches I.P.S. ..... (c) Pool inlets and outlets shall be provided and arranged to produce uniform circulation of water and the maintenance of uniform chlorine residual throughout the pool; there shall be at least four (4) inlets for the smallest pool. ..... (d) Provisions shall be made to adjust the flow through all inlets. ..... (e) Maximum flow rates (in gpm) through various sized inlet branches shall not be more than as listed below: ..... Size: | 1" | 1¼" | 1½" | 2" GPM: | 10 | 20 | 30 | 50 (f) In pools with surface area greater than one thousand five hundred (1,500) square feet or length in excess of sixty (60) feet, inlets shall be placed around the entire perimeter. In any case, an adequate number of inlets shall be provided, properly spaced and located to accomplish complete recirculation and the assurance of uniform and adequate sterilizing medium at all times. .....
(Code 1986, § 33-81)
Ask a question about Chattanooga law
Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.