7.13.6 - Electric Easement Requirements.
In all cases where primary electric lines which will feed adjacent properties are installed on private property, the following standards shall prevail: A. All easements shall be dedicated as public utility easements and shall be sized per Table 7.13-L, Table 7.13-M, Table 7.13-N. The general criteria to define typical easement widths and sizes are listed in the following tables: Table 7.13-L: Typical Overhead Electric Line Easement Widths Line Type | Along Lot Frontage | Through Interior of Lot 138 KV Transmission Lines | As required to accommodate clearance specified in Section 7.13.4 | 75 feet (Line to be centered in easement) 69 KV Transmission Lines | As required to accommodate clearance specified in Section 7.13.4 | 60 feet (Line to be centered in easement) 13.2 KV Distribution | As required to accommodate clearance specified in Section 7.13.5 (Not required when clearance is accommodated by building setback) | 35 feet (Line to be centered in easement) Table 7.13-M: Typical Underground Electric Line Easement Widths Line Type | Along Lot Frontage | Through Interior of Lot 13.2 KV Distribution | 8 feet (Line typically installed 3-4' from R.O.W. line) | 16 feet (Line typically installed 3-4' from edge of easement) 13.2 KV Distribution Duct Bank (Multiple Feeders) | 20 feet (Duct bank typically centered in easement) | 20 feet (Duct bank typically centered in easement) Transmission Duct Banks | 20 feet | 20 feet Table 7.13-N: Typical Pad-Mounted Electric Equipment Easement Sizes Equipment Type | Equipment Easement Single Phase Distribution Transformer | 10 feet by 10 feet Three Phase Distribution Transformer | 16 feet by 16 feet Distribution Switchgear | 18 feet by 30 feet Other Pad-Mounted Equipment | As Needed B. Easement widths and sizes are subject to change at the discretion of Denton Municipal Electric (DME) in accordance with the applicable criteria manual. C. DME may allow a utility easement to be dedicated within a fire lane for underground electric distribution lines in some cases, provided that equipment easements are dedicated outside of the fire lane for pad-mounted equipment. Figure 7.13-A: Equipment Easement Location [image omitted; see the official code] D. Fences within utility easements are generally prohibited, subject to the following: 1. Fences shall not be built within or across dedicated utility or electric easements. DME, at their discretion, may allow fences to be built across an easement if access gates at least 12 feet wide are built. 2. Any existing fence located within dedicated utility or electric easements that conflicts with the purpose and intent of the easement may be removed by the city at any time. 3. The city is under no obligation to repair or replace any fence that is damaged or removed that encroaches within a dedicated easement for the purposes of operating, maintaining, replacing or installing electric facilities within the dedicated easement. E. Employees of the city shall have the authority to enter premises at any reasonable time in the regular line of duty for the purpose of inspecting, repairing or constructing any electric line or any electric meter, etc. The landowner and occupant are responsible for any construction activities occurring over or within any on-site utility in a utility easement. F. If utility inspection or repair or reconstruction is necessary, any pavement, structure, or improvement damaged within a dedicated utility or electric easement, shall not be the responsibility of the city for any repairs, but shall be the sole responsibility of the owner. G. The landowner assumes responsibility for any and all improvements placed within a utility or electric easement at their own risk. Additionally, the provisions of this section do not permit or supersede the limits and restrictions prescribed by the conditions of any existing utility easement for allowing improvements to be placed within utility easements. H. The following shall not be installed or planted within a utility or electric easement without approval by the city: 1. Trees; and 2. Any structures, including retaining walls and signs. No part of a structure, including its underground foundation, shall encroach into an easement. I. The following items are typically allowed to be installed within a utility or electric easements: 1. Drive approaches and parking lots (alignment within drive aisles is preferred); 2. Sidewalks; and 3. Grass and small shrubbery.
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.