For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.145.280 — Stream relocation

Federal Way Revised Code (The Federal Way Revised Code is current through Ordinance 26-1052, passed September 1, 2026.) · Federal Way Revised Code § 19.145.280

Corpus is an independent public-information project, not the official City of Federal Way website. Stable reference: corpuslaw.us/code/90a8bf50-1eae-4df3-8760-5d32c97f6fd3

19.145.280 Stream relocation.

(1) Relocation of a stream will be permitted only as part of a public project for which an essential public facility, public utilities, or other public improvements have been granted a partial exemption from the director or if the relocation is associated with compensatory mitigation or restoration project. Any proposed relocation is subject to all of the conditions and restrictions of this section. (2) As part of any request under this section, the applicant must submit a stream relocation plan with the critical areas report that shows the following: (a) The creation of a natural meander pattern; (b) The formation of gentle side slopes, at least two feet horizontally to one foot vertically, and the installation of erosion control features for stream side slopes; (c) The creation of a narrow sub-channel, where feasible, against the south or west bank; (d) The utilization of natural materials, wherever possible; (e) The use of vegetation normally associated with streams, including primarily native riparian vegetation; (f) The creation of spawning and nesting areas, wherever appropriate; (g) The re-establishment of the fish population, wherever feasible; (h) The restoration of water flow characteristics compatible with fish habitat areas, wherever feasible; (i) The filling and revegetation of the prior channel; and (j) A proposed phasing plan specifying time of year for all project phases. (3) The city will allow a stream to be relocated only if water quality, habitat and stormwater retention capability of the streams will be the equivalent or improved by the relocation. Convenience to the applicant in order to facilitate general site design shall not be considered. (4) Prior to diverting water into the new channel, a qualified professional shall inspect the new channel following its completion and issue a written report to the director stating that the channel complies with the requirements of this section. (5) The amount of flow and velocity of the stream may not be increased or decreased as the stream enters or leaves the subject property.

(Ord. No. 15-797, § 22, 6-16-15.)

Ask a question about Federal Way law

Corpus searches the Federal Way sections it holds and shows the ones that match, with their citations. Free, no sign-in.