Sec. 18-246. - Bridging.
In all ceilings, floors, attic, and flat roof joist framing, there shall be not less than one line of bridging for each eight feet of span and the bridging shall not be less than one-inch by three-inch lumber double-nailed at each end, or equivalent metal lateral bracing of equal rigidity secured at the intersections. A line of bridging shall also be required at supports where adequate lateral stiffness is not otherwise provided. Solid bridging is also acceptable. Where two-inch by six-inch ceiling joists are used, a minimum two-inch by four-inch stay-lathe may be substituted for required bridging. Such stay-lathe shall be spiked securely at each joist and at each end to either stud or rafter.
(Code 1973, § 30.29.060)