Sec. 18-254. - Hung ceiling.
Ceiling joists, when parallel to roof joists, shall be two inches by four inches at the same spacing as the joists above and hung by not less than one-inch by four-inch hangers spaced at not more than six feet. Ceiling joists, when at right angles to roof joist, shall be two inches by four inches spaced 16 inches on center and hung by not less than two-inch by two-inch hangers spaced at not more than six feet.
(Code 1973, § 30.29.140)