§ 18-255 — Joist headers and trimmers
Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-255
Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/3bdead7a-f74f-47ef-be5c-5233e5226ce8
Sec. 18-255. - Joist headers and trimmers.
All joist headers more than four feet in length and their trimmers shall be doubled. All tail beams or joists which are more than six feet in length shall be hung in approved joist or beam hangers, or shall be fastened by approved metal connectors. All double trimmer joists shall be spiked together. A minimum two-inch by two-inch ledger strip may be used in lieu of hangers or connectors.
(Code 1973, § 30.29.150)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.
