Sec. 18-255. - Joist headers and trimmers.

All joist headers more than four feet in length and their trimmers shall be doubled. All tail beams or joists which are more than six feet in length shall be hung in approved joist or beam hangers, or shall be fastened by approved metal connectors. All double trimmer joists shall be spiked together. A minimum two-inch by two-inch ledger strip may be used in lieu of hangers or connectors.

(Code 1973, § 30.29.150)