For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.28.020 — Purpose

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.28.020

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/5668367a-f827-46bb-bf86-9db7b640022e

15.28.020 - Purpose.

It is generally acknowledged that the City will experience earthquakes in the future due to its proximity to both the San Andreas and Hayward faults, and may reasonably be expected to experience moderate to severe ground shaking in the event of a significant earthquake. Such ground shaking may result in serious injury or death due to damage or collapse of buildings in Oakland. Buildings constructed of unreinforced masonry have been widely recognized for experiencing life safety hazardous damage including partial or total collapse during moderate to strong earthquakes. The purpose of this Chapter is to promote public safety by mitigating the potential hazards of those buildings in Oakland that were built of unreinforced masonry walls and were subject to the building code prior to November 26, 1948 (the effective date of the building code requiring earthquake resistant design of buildings). The purpose of this Chapter is also to promote public safety and welfare by reducing the risk of death or injury that may result from the effects of earthquakes on existing unreinforced masonry buildings. The provisions of the retrofit standards for unreinforced masonry buildings in this Chapter are intended as minimum standards to reduce the risk of life loss or injury. Compliance with these provisions will not meet the requirements of the current code and will not necessarily prevent loss of life or injury, or prevent earthquake damage to rehabilitated buildings. Furthermore, the intent of this Chapter is to mandate a portion of the state recommended standard (Uniform Code for Building Conservation). In doing so, it is the intent of this Chapter to continue to construe the building as a potential hazardous building upon completion of the mandatory portion of this Chapter and until such time that the building is upgraded to the Uniform Code for Building Conservation.

(Prior code § 18-6.02)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.