15.28.090 - Mandatory retrofit standards for frame buildings with URM walls and buildings with URM veneer.

The owner of a framed building with URM infill walls and buildings with URM veneer shall upgrade his or her building to the retrofit standards specified in this Section, within the time specified in Section 15.28.070C. As a minimum, the following elements shall be upgraded to mitigate the potential falling hazards: A. Brace or reinforce parapets and remove, upgrade or repair nonstructural falling hazards. In designing the upgrade for these items the current code shall apply; B. Stairways, corridors, exit balconies, exit courts and exit passageways in all buildings covered by this Chapter shall be protected from falling hazards; C. Walls, parapets, and other building elements which due to their locations or the height of the adjacent structure pose negligible hazards to life and adjacent property in the event of failure or instability such as parapets on the sides of buildings which are adjacent to another building of equal or more in height, may be excluded from the required work within the specified time in Section 15.28.070C provided the owner agrees to execute an agreement with the city to defend, hold the city harmless and indemnify the city for any damage, injury or loss of life that may occur due to the absence of the upgrade work and agrees to perform the upgrade work at some future time to abate any hazards that may arise as a result of changed conditions to the adjacent structure. The owner must record the agreement with the County Recorder, and supply a copy of the recorded agreement to the city. Exception: Buildings with only some interior URM walls composed of structural URM elements that provide less than one percent of the total existing lateral resisting system in all directions and/or nonstructural URM interior wall elements as defined in this Chapter, will not be subject to the structural upgrade standard in this Section. When required by the Building Official, the engineer/architect shall provide an acceptable analysis and documentation to substantiate that the building qualifies for this exception.

(Prior code § 18-6.09)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.