15.28.080 - Voluntary and mandatory retrofit standards for bearing wall buildings.
A. General. The owner of a building with URM bearing walls shall upgrade his or her building to the mandatory retrofit standards specified in subsection B of this Section, within the time specified in Section 15.28.070C. Upgrading the building to the voluntary standards specified in subsection C of this Section will cause the removal of the building from the city's inventory list of URM buildings as indicated in Section 15.28.070D. Exception: Buildings with only some URM walls (that includes URM bearing walls) will not be subject to the upgrade standard in this Section and will be removed from the city's URM list provided: 1. All the URM wall elements provide less than one percent of the total lateral load resisting system in all directions as defined in this Chapter, and less than five percent of the vertical load carrying system. 2. When required by the Building Official, the engineer/architect provides acceptable analysis and documentation, to substantiate compliance with this exception. B. Mandatory Retrofit Standards for Bearing Wall Buildings. 1. Building Elements To Be Upgraded. As a minimum, the following elements shall be upgraded to mitigate potential falling hazards: a. Secure the roof and floors to the building's exterior walls if such attachment is lacking or determined as inadequate. The connections between roof/floors and walls shall be designed for the out of plane forces on the walls (tension blots); b. Brace or reinforce parapets; c. Remove, upgrade or repair nonstructural falling hazards; d. Stairways, corridors, exit balconies, exit courts and exit passageways in all buildings covered by this Chapter shall be protected from falling hazards. 2. Design Standard and Excluded Building Elements. In designing the upgrades for the above items, the minimum lateral forces specified in the current UCBC shall apply to elements in subsection (B)(1)(a) of this Section and current code shall apply to elements in subsections (B)(1)(b) and (c) of this Section. Walls, parapets, and other building elements which due to their locations or the height of the adjacent structure pose negligible hazards to life and adjacent property in the event of failure or instability, (such as parapets on the sides of buildings which are adjacent to another building of equal or more in height) may be excluded from the required work within the specified time in Section 15.28.070C provided the owner agrees to execute an agreement with the city to defend, hold the city harmless and indemnify the city for any damage, injury or loss of life that may arise as a result of changed conditions to the adjacent structure (such as removal of the adjacent building). The owner must record the agreement with the County Recorder, and supply a copy of the recorded agreement to the city. C. Voluntary Retrofit Standards for Bearing Wall Buildings. If the owner elects to voluntarily upgrade his or her building to the retrofit standard in this subsection his or her building will be removed from the city's potentially hazardous URM list. 1. The entire building shall be retrofitted in accordance with the current UCBC. All destructive materials testing in accordance with the current UCBC is required only when those elements are used as part of the structural design. The decision of whether of not to test existing materials is fully the responsibility of the engineer/architect, and the city assumes no liability for damage, injury or harm caused by such testing. However, in the absence of acceptable test data, the engineer/architect shall use allowable stresses from existing materials in accordance with the current UCBC or as approved by the Building Official. 2. Proposed alterations, additions, restoration and rehabilitation of buildings with URM bearing walls shall include an evaluation of the effects of such work to the building in its entirety. This shall include, but not be limited to, an investigation of the effects of any induced eccentricity and changes in the foundation and in story stiffness as a result of the proposed improvements. 3. Stairways, corridors, exit balconies, exit courts and exit passageways in all buildings covered by this Chapter shall be protected from falling debris. Vertifical supports for stairways shall be shown to retain their integrity after an earthquake. Exception: When the lower story or stories of a building are of URM construction (or, contain at least one URM bearing wall) but the structural system of the upper stories consists of the only wood frame or steel stud construction, then only the URM stories need be upgraded to the standards set forth in subsection C of this Section, and the other stories need not be upgraded. NOTE: This alternative does not satisfy the upgrade standard referenced in Sections 15.28.110 and 15.28.120.
(Prior code § 18-6.08)
Ask a question about Oakland law
Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.