For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.28.100 — Engineering analysis reports (EARs)

Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.28.100

Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/da32ab9f-93ea-4aa7-8ab6-89f61cc5350a

15.28.100 - Engineering analysis reports (EARs).

A. General. The EARs shall be filed with the applicable building permit and prepared to demonstrate the proposed permit work will comply with the applicable standards specified in Section 15.28.080 for the bearing wall buildings or Section 15.28.090 for frame buildings with URM infill walls and for buildings with URM veneer. B. Preparer of Report. Building owners shall employ a civil or structural engineer or architect, registered by the state of California, herein called "engineer/architect," to prepare the engineering plan and calculations acceptable to the Building Official for the proposed retrofit work applicable to the building permit application and to prepare the EARs in accordance with this Section. C. Scope of Analysis. The scope of analysis need only address the proposed permit work with the following information: 1. Building Permits for Mandatory Upgrade Work. The following analysis for the mandatory upgrade of URM bearing wall buildings and the upgrade for frame buildings with nonbearing URM walls and for buildings with URM veneer shall be performed: a. Parapet stability; b. Nonstructural falling hazards anchorage and stability; c. Wall to diaphragm anchorage for tension anchors (for bearing wall buildings only); d. Evaluation of falling hazards for exits. 2. Building Permit for Voluntary URM Bearing Wall Upgrade Work. The following analysis for the voluntary upgrade of URM bearing wall buildings shall be performed: a. General compliance with the current UCBC: i. Required retrofitting, ii. Materials testing; b. Structural analysis: i. Out-of-plane loads on walls; tension anchors and bracings, ii. Wall to diaphragm anchors for shear, iii. In-plane strengthening of walls; repairs and repointing, iv. Diaphragm capacity, v. Other analysis as required by current UCBC, vi. Integrity of stairway and falling hazards for exits. D. Format of Report. The engineering reports for all building permits shall conform with the format in this subsection. This format is not meant to be a constraint on the engineer/architect preparing the report, but rather it shall be considered as the minimum acceptable information to be submitted. 1. General Information. a. Date report is completed; b. The building address with the County Assessor's parcel number; c. Name of building (if any); d. Name, address, and telephone number of owner; e. Names, addresses, and telephone numbers of property beneficiaries; f. The type of occupancy uses within the building and the occupant loads; g. The number of residential, commercial and other units in the building; h. The dates of original design, construction, additions or substantial structural alternations (if known) of the building; i. The name of the original designer and contractor (if known), and the name and address of the designer and contractor (if known), for any subsequent additions or substantial structural alternations; j. Affirmative of whether or not the original building plans are available and name and address of person who has plans; k. Scaled plan to show footprint of building in relation to property line (if known), sidewalk, and street area, and adjacent buildings; l. Photos or sketches of elevation to show adjacent buildings. 2. Summary of Existing Conditions. The engineer/architect shall investigate the building for compliance with the applicable standard in Section 15.28.080 or 15.28.090 related to the proposed building permit application, describe the vertical load carrying systems and identify any URM bearing walls. The engineer/architect shall also include a description of all parapets and nonstructural falling hazards, their construction, supports, materials and any testing and test data. 3. Deficiencies and Corrective Measures. The engineer/architect shall submit structural analysis in accordance with the applicable provisions in subsection C of this Section to identify deficiencies and design corrective measures to meet the minimum requirements of the applicable retrofit standards. 4. Proposed Upgrade/Corrective Work. The engineer/architect shall describe the upgrades or corrective work required for the building under the proposed building permit and provide an estimated cost for the work. 5. Engineer/Architect Certification. Name, work address, work phone number, California state professional license number and signature of engineer/ architect who authored the report.

(Prior code § 18-6.10)

Ask a question about Oakland law

Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.