§ 15.28.060 — Definitions
Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Municipal Code § 15.28.060
Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/b4ef9848-efd3-4242-92fc-a59c3409da31
15.28.060 - Definitions.
For the purposes of this Chapter, certain words, phrases, terms and their derivatives shall be construed as specified in this Section. Words, phrases, and terms that are used in this article, but not specifically defined, shall have the meaning set forth in the applicable local, state or federal code, if appropriate. Other such words, phrases and terms shall be accorded their ordinary meanings. "Building," for the purpose of determining occupant load, means any contiguous or interconnected structure; for purposes of engineering evaluation, means the entire structure or portion thereof which will respond to seismic forces as a unit. "Complexity of work," for the purpose of prioritizing buildings, shall be based on cost and difficulty of upgrading work. "Current code (current UBC)" means the current edition of the California State Building Code, as amended from time to time and as amended by the City of Oakland. "Current Uniform Code of Building Conservation (current UCBC)" means the seismic provision for unreinforced masonry bearing wall buildings in the current edition of the Uniform Code of Building Conservation as adopted by the California State Building Code. "Day" means calendar day. "Historic structure" means a structure that meets one of the following requirements: 1. Is listed on the National Register of Historic Places; 2. Is a California Registered Historical Landmark or is a California Point of Historical Interest; 3. Is a landmark pursuant to Section 17.102.030 of the Oakland zoning regulations; 4. Is contributory to an S-7 preservation combining zone pursuant to Section 17.84.010 of the Oakland zoning regulations; or 5. Has received an "A" or "B" rating in the Oakland cultural heritage survey. Prior to the issuance of a building permit for work pursuant to this Chapter, the URM building shall be surveyed and rated by the Oakland cultural heritage survey to determine if the building is a historic structure, as defined herein. "Masonry" means that form of construction composed of stone, brick, concrete, gypsum, hollow clay tile, concrete, block or tile or other similar building units or materials or combination of these materials. "Nonstructural falling hazards" means any ornamentation and appendage on the exterior of the building that is constructed of dense materials such as masonry or concrete attached directly or indirectly to unreinforced masonry, which may fall onto pedestrians or adjacent buildings or occupants of buildings, such as cornices, chimneys, balconies, stacks, towers, decorative statuary, and roof top tanks or equipment on buildings. For the purpose of this Chapter, lintels, veneers and sills shall not be considered falling hazards. "Nonstructural URM wall elements" means any URM wall element which does not participate in resisting lateral or vertical forces on the building by design or actual condition. "Owner" means any individual or group of individuals or firm or any other entity holding legal or equitable title to the real property. "Potentially hazardous URM building" means any URM building, other than those exempted from this Chapter per Section 15.28.030 that does not meet the applicable retrofit standards specified in Sections 15.28.080 and 15.28.090. "Reinforced masonry" means any masonry construction that meets the minimum reinforcing requirements which are as follows: the minimum area of reinforcing bars shall be not less than 0.001 times the gross cross-sectional area of the wall, not more than two-thirds of which may be used in either direction and no required vertical reinforcement shall be less than three-eighths inch in diameter. "Structural deficiencies" means structural elements which do not meet the applicable standards identified in Sections 15.28.080 and 15.28.090. "Structural URM wall elements" means any non-bearing URM wall element, whether intentionally designed or not, that participates in residing lateral forces caused by earthquake motion. "Unreinforced masonry (URM)" means any masonry construction that does not meet the minimum reinforcement requirements of reinforced masonry, as defined in this Section. "URM building" means any building containing walls constructed, wholly or partially, with unreinforced masonry. Types of unreinforced masonry buildings include but are not limited to: 1. "URM bearing wall building or structure" means any structure which has unreinforced masonry wall which provides support for a floor or roof for which the total superimposed load exceeds one hundred (100) pounds per linear foot of wall. 2. "Frame building or structure with URM walls" means any structure with a structural frame of concrete, steel, or wood, with either infill walls or nonbearing walls constructed of unreinforced masonry or structural URM wall elements. 3. "Building with URM veneer" means any structure other than 1 and 2 of this definition with nonstructural unreinforced masonry exterior facing for the purpose of ornamentation, protection or insulation.
(Prior code § 18-6.06)
Ask a question about Oakland law
Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
