§ 19.28.170 — Septic tank requirements
Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 19.28.170
Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/edc09ab5-2132-4e63-adb6-669d19a5b96a
§ 19.28.170: Septic tank requirements.
A. All conventional OWTS require the use of a septic tank to allow for the removal of solids in the wastewater prior to being discharged to the dispersal field. Alternative OWTS also require a septic tank unless a settling chamber is a component of the treatment unit. B. Septic tank requirements: 1. Septic tanks must be certified by the International Association of Plumbing and Mechanical Officials (IAPMO). 2. The tank shall be watertight and possess two chambers. 3. Septic tanks shall be certified by the manufacturer to allow for burial without being water filled to allow for routine maintenance or to be used as a holding tank as needed. 4. Septic tanks shall be installed per the manufacturer's instructions. 5. The bottom of the excavation for the tank shall extend into native or compacted soils to eliminate potential settling issues. 6. Septic tank location must take into account maintenance and pumping requirements including vehicle access; and distance and elevation lift to pumper truck. 7. All tanks must have a capped tee or a 90-degree elbow fitting on the inlet to prevent gas exchange between the tank and the house plumbing. Inlet tees must extend at least 14 inches below the liquid level. 8. Outlet tees must be uncapped and must extend at least 12 inches below the liquid level. 9. The outlet elevation shall be between two and six inches lower than the inlet elevation to ensure proper fall without a significant loss of volume. 10. Fall between the outlet of the septic tank and the dispersal field shall be continuous with a minimum fall that that ensures the outlet pipe is four inches higher than the top of the seepage pit system or four inches above the top of the leach rock or other components used in the dispersal system on a level system, or a distribution box if multiple seepage pits or leach lines are constructed. 11. Septic tanks with greater than six inches of cover must have risers to within six inches of finished grade. Risers and lids that are at or above grade must be watertight and lockable or require tools to be opened. 12. Septic tank risers must have a current IAPMO certification prior to use. Concrete risers and lids must be constructed of Type V concrete or be protected from corrosion from sewer gases. The interior diameter of the riser shall be a minimum of 18 inches. 13. Effluent filters must be IAPMO approved if they are to be installed as part of the outlet tee. 14. Septic tanks installed in areas of vehicular traffic must be certified to withstand the proposed loads or have an engineered traffic slab installed to accommodate the proposed loads. 15. Minimum tank size is 1,000 gallons for residential and 750 gallons for nonresidential structures. 16. Septic tanks shall be sized according to anticipated wastewater flows from the structure(s). The following standard sizes shall apply: (i) one- to three-bedroom single-family dwelling (0 to 450 GPD) 1,000 gallons; (ii) four-bedroom single-family dwelling (450 to 600 GPD) 1,200 gallons; (iii) five- to six-bedroom single-family dwelling (601 to 900 GPD) 1,500 gallons; and (iv) flows greater than 900 GPD must utilize the following formula to determine minimum tank sizing: 1,125 gallons + (0.75)(flow in GPD). 17. The permitted plan set shall contain a note requiring the septic tank to be filled with water, without leakage, at the time of the first inspection.
( Ord. No. 911 § 2, 2017 ; Ord. No. 936 § 2, 2018 )
Ask a question about Rancho Cucamonga law
Corpus searches the Rancho Cucamonga sections it holds and shows the ones that match, with their citations. Free, no sign-in.