§ 19.28.220 — Alternate onsite wastewater treatment systems siting and operational requirements—Variances permissible

Municipal Code, City of Rancho Cucamonga, California (Code 2026-09-02) · Rancho Cucamonga Municipal Code § 19.28.220

Corpus is an independent public-information project, not the official City of Rancho Cucamonga website. Stable reference: corpuslaw.us/code/95797233-8d2e-4ce4-8586-4035c1997e1d

§ 19.28.220: Alternate onsite wastewater treatment systems siting and operational requirements—Variances permissible.

A. Property owners may apply to building and safety services to establish alternative OWTS siting and operational requirements where it is determined by building and safety services that alternative requirements will provide equivalent level of environmental protection. B. Variances will not be granted in the following circumstances: 1. Where the proposed OWTS presents a substantial likelihood of discharging sewage, impure waters, or any matter or substance offensive, injurious, or dangerous to health so as to cause any of the following to occur: a. Sewage, impure waters, or any matter or substance offensive, injurious, or dangerous to health to empty, flow, seep, or drain onto the surface of any land. b. Sewage, impure waters, or any matter or substance offensive, injurious, or dangerous to health to empty, flow, seep, drain into, or affect any well, spring, stream, river, lake, or other waters. c. Result in any condition which is unsafe, dangerous, or creates a nuisance. 2. Above surface discharge. Variances will not be granted for any OWTS which utilizes any form of effluent disposal discharging on, or above, the post installation ground surface; this includes, but is not limited to, sprinklers, exposed drip lines, free-surface wetlands, and ponds. 3. Sewer availability. Variances will not be granted for any OWTS where there is a public sewer available. The building and safety services department may require a "Will or Will Not Serve" letter Cucamonga Valley Water District with each new or replacement OWTS proposal to evaluate the proximity and availability of community systems to the proposed OWTS site. This will ensure septic systems are only installed in areas where a sewer is unavailable. The "Will or Will Not Serve" letter must include the following: (i) parcel number for the property where the OWTS is being proposed; (ii) distance to the nearest available sewer line; and (iii) whether or not the sewering entity will provide service to the parcel. The "Will or Will Not Serve" letter must be completed and signed by the appropriate official representing the sewering entity and be filed with the building and safety services department prior to submittal of the percolation report/plot plan, or upon request once the percolation report/plot plan has been submitted. 4. Sewer requirement. Connection to a public sewer system is required within established sewer service districts and outside such districts when required by the RWQCB. Developments must connect to a sewer system when the nearest property line is within 200 feet of a sewer line. This requirement will be increased by 100 feet for each dwelling unit within the development. 5. Ground slope. Variances will not be granted for slopes greater than a 30 percent incline without a slope stability report approved by a qualified professional. Refer to natural ground slope for more information regarding natural ground slope requirements. 6. Leaching areas. As referenced in the current adopted California Plumbing Code, Appendix H — Private Sewage Disposal Systems — Section H 301.1 Leaching Chambers that comply with IAPMO PS 63 and bundled expanded polystyrene synthetic aggregate units that comply with IAPMO IGC 276 shall be sized using the required area calculated using Table H 201.1(3) with a 0.70 multiplier. 7. Supplemental treatment. OWTS utilizing supplemental treatment require periodic monitoring or inspections. No variances will be granted for supplemental treatments that are unable to meet this requirement. 8. Depth to groundwater. No variance will be granted for OWTS with a depth from the bottom of the dispersal system to groundwater less than five feet. The exception to this will be for seepage pits which shall have a separation no less than 10 feet. 9. Recreational vehicle (RV) holding tanks. No variances will be granted for OWTS dedicated to receiving significant amounts of wastes, which are dumped from RV holding tanks. 10. Class V injection wells. United States Environmental Protection Agency (USEPA) requirements apply to underground injections control systems for OWTS. Subsurface disposal systems including leach fields and seepage pits shall comply with USEPA Underground Injection Control requirements when classified as a Class V injection well. Subsurface disposal systems with at least one of the following characteristics are classified as Class V wells: (i) the system has the capacity to serve 20 or more persons per day; (ii) the system receives wastewater other than domestic wastewater such as that generated by manufacturing, chemical processing, industrial fluid disposal, automotive repair, or recycling; or (iii) the system receives sewage containing biological agents (such as wastewater from recreational vehicles or portable toilets). Disposal systems that are classified as Class V wells must be registered with USEPA.

( Ord. No. 911 § 2, 2017 ; Ord. No. 936 § 2, 2018 )