§ 81.2.12 — Exit door to roof. [Geological/Climatic]
Municipal Code, City of Torrance, California · Torrance Municipal Code § 81.2.12
Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/5184ad8e-b5f1-4a8c-b595-03f03d021d3b
§ 81.2.12: Exit door to roof. [Geological/Climatic]
Section 1011.12.3 of the California Building Code, 2025 Edition, is hereby added to read in its entirety as follows: 1011.12.3 Exit Door to Roof. The exit doors at the roof shall be locked at all times and shall not comply to Section 1010.2.4. Locking mechanisms shall have the capacity of being unlocked simultaneously without unlatching upon a signal from the central control station or the fire and sprinkler alarm system if a central control system is not required. Upon failure of electrical power, the locking mechanisms shall be retracted to the unlocked position.