§ 81.2.6 — Fire ratings between similar occupancies. [Climatic]

Municipal Code, City of Torrance, California · Torrance Municipal Code § 81.2.6

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/01e145b5-a892-4ec9-b45c-f5974705530a

§ 81.2.6: Fire ratings between similar occupancies. [Climatic]

Section 508.4.5 is hereby added to the California Building Code, 2025 Edition, to read in its entirety as follows: 508.4.5 Fire Ratings Between Similar Occupancies. Where more than one (1) tenant or owner occupies a building and has the same character of occupancy, such tenants or owners shall be separated by a minimum of one-hour fire resistive construction, continuous from the ground to the roof. Exceptions: 1. Where all portions of the building, including attics, are protected by an automatic fire extinguishing system in accordance with NFPA Standards. 2. In all Type I buildings. 3. In multi-story buildings, separation walls may terminate at floors provided the floor system is of a one (1) hour minimum fire resistive construction.