§ 81.2.7: Automatic fire extinguishing systems. [Climatic]

Section 903.2 of the California Building Code, 2025 Edition, is hereby amended to read as follows: 903.2 Where Required. An approved automatic sprinkler system must be provided in new buildings and structures for all occupancies. In addition, automatic sprinkler system shall be provided in the location described in section 903.2.1, 903.2.2, 903.2.7, 903.2.8.1.1, 903.2.9, 903.2.10.2 and 903.2.11.3. Exception: New detached buildings under 1000 square feet in size subject to approval of Building Official. 903.2.1 Group A Occupancies. 903.2.1.1 Group A-2. An automatic sprinkler system shall be provided for Group A-2 occupancies where one of the following conditions exists: 1. | The cumulative building floor area exceeds 4,000 square feet (465 m2); 2. | The fire area has an occupant load of 100 or more; or 3. | The fire area is located on a floor other than the level of exit discharge. 903.2.2 Group B Occupancies. 903.2.2.1 General. An automatic sprinkler system shall be installed in Group B, Occupancies where the floor area exceeds 12,000 square feet on any floor or 12,000 square feet on all floors or in Group B occupancies more than three stories in height. The area of mezzanines shall be included in determining the areas where sprinklers are required. 903.2.2.2 Eating Establishments. An automatic sprinkler system shall be installed throughout every building containing one or more eating establishments with a total accumulative floor area in excess of four thousand (4000) square feet. 903.2.2.3 Group B Ambulatory Healthcare Facilities. An automatic sprinkler system shall be installed throughout all fire areas containing a Group B ambulatory health care facility occupancy when either of the following conditions exists at any time: 1. | Four or more care recipients are incapable of self-preservation. 2. | One or more care recipients who are incapable of self-preservation are located at other than the level of exit discharge serving such an occupancy. 3. | In rooms or areas with special hazards such as laboratories, vocational shops and other such areas where hazardous materials in exempt amounts are used or stored. 4. | Throughout any Group E structure greater than 20,000 square feet (1155 m2) in areas, which is separated into two or more buildings by fire walls of less than four-hour fire resistance rating without openings. 903.2.7 Group M. An automatic sprinkler systems shall be provided throughout buildings containing Group M occupancy where one of the following conditions exists: 1. | Where a Group M fire area is located more than three stories above grade plane. 2. | Where the combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 12,000 square feet (1115 m2). 3. | A Group M occupancy is used for the display and sale of upholstered furniture. 4. | The structure exceeds 12,000 square feet (1115 m2) contains more than one fire area containing a Group M occupancy, and is separated into two or more buildings by fire walls of less than 4-hour fire resistance rating without openings. 903.2.8.1.1 Existing R-3 Occupancies. An automatic sprinkler system must be provided throughout every existing R-3 occupancy when a 1,000 square foot or greater addition occurs established by the Building Code Official. 903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout all building containing a Group S-1 occupancy where one of the following conditions exists: 1. | Where a Group S-1 fire area is located more than three stories above grade plane. 2. | The combined area of all Group S-1 fire areas on all floors, including any mezzanines, exceeds 12,000 square feet (1115 m2). 3. | A Group S-1 fire area used for the storage of commercial trucks or buses where the fire area exceeds 5,000 square feet (464 m2). 903.2.10.2 Parking Garages. In parking garages over 10,000 square feet in area, incorporated within and part of Group R Occupancies and not otherwise covered by this code or the California Building code. 903.2.11.3 Building 40 feet or more in height. An automatic sprinkler system shall be installed throughout buildings with a floor level having usable floor area that is located 40 feet or four (4) stories above the lowest level of fire department vehicle access. Exceptions: 1. | Airport control towers. 2. | Open parking structures. 3. | Occupancies in Group F-2.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.