Sec. 13-242. - Water distribution.

(a) Connection to public system. The developer shall install or have installed a system of water mains and connect such systems to a public water supply provided that: (1) A water distribution system supplying water from an approved treatment facility shall be provided to serve all parcels of the subdivision. The pipes shall be sized to provide fire protection and an adequate supply of domestic water for all reasonably anticipated construction and occupant demands. The engineer of record shall submit to the city engineer complete calculations showing the capability of the proposed water distribution system to provide fire flows with a minimum residual pressure of twenty (20) pounds per square inch. The calculations of required fire flows for selected locations or developments, in gallons per minute shall take into account the construction, occupancy, exposure and communication as outlined in the I.S.O. (Insurance Services Organization) Fire Suppression Rating Schedule, latest edition. (2) A connection to each lot shall be installed prior to the paving of the street if possible. The city commission may require the installation of water mains and appurtenances which are in excess of the subdivision design needs and mutually establish an equitable reimbursement program with the developer. (b) Standards of design and construction. The water distribution system shall conform to all requirements and/or minimum standards of state and county government unless more stringent standards are established in this article. (1) No pipe other than service lines shall be smaller than six (6) inches in nominal diameter. (2) Water mains shall be ductile iron pipe, in conformance to ANSI/AWWA C-151/A21.51 and installed in rights-of-way and unless changed by reason of interference with existing utilities, the platting of half streets or other valid cause, they shall be on the south and east sides of the rights-of-way. In general, the offset from the property line shall be ten (10) feet. (3) The minimum cover on all water mains shall be thirty (30) inches. Service crossings shall have a minimum of twenty-four (24) inches of cover and be constructed in accordance with the city's utility and engineering standards manual. Casings shall be provided for all service lateral underneath pavements. Casings shall be extended to two (2) feet beyond edge of pavement and/or four (4) feet from the connection to the water main. Steel casing pipe, black iron or galvanized shall be used and shall conform to ANSI/AWWA C800 Section A and B and ASTM Specifications A 120 or poly vinyl chloride (PVC) schedule 40 shall conform to ASTM D1785. (4) Terminal blowoff connections shall be installed on all dead-end lines not equipped with a fire hydrant in accordance with the city's utility and engineering standards manual. (5) Fire hydrants to serve residential districts shall be placed on lines six (6) inches or larger and shall be spaced so that all building areas of lots and parcels are within three hundred (300) feet of a hydrant as measured along street centerlines. In commercial and industrial districts, the minimum line size shall be eight (8) inches. Hydrants shall be provided along major streets, spaced at a minimum distance of eight hundred (800) feet or as determined by the city engineer. A fire hydrant shall be placed a minimum of one hundred fifty (150) feet from public roadway centerline intersections. Fire hydrants shall be installed in accordance with the method shown in the city's utility and engineering standards manual. The city engineer may require special spacing in commercial and industrial districts depending on use. (6) Each hydrant shall be capable of delivering the required flow as determined by ISO requirements with a residual pressure of not less than twenty (20) pounds per square inch and shall be provided with auxiliary gate valve. (7) Valves shall be so located that a break at any point in the system may be isolated without causing interruption to service of more than one (1) commercial or business block or two (2) residential blocks and they shall be situated on the extended property line of intersecting streets where practical. In addition, valves shall be installed so that the maximum length of pipe between any two (2) valves is one thousand (1,000) linear feet for residential areas and eight hundred (800) linear feet for commercial and/or industrial areas. (8) Small meters, defined as five-eighths to two (2) inches in diameter, shall be set in precast concrete, or other approved material, boxes and located inside property lines. Large meters, defined as those greater than two (2) inches in diameter, and their controlling valves shall be located in concrete vaults with removable plates or grating covers. The meters and backflow preventers shall be placed inside property lines on the right-of-way or easement lines outside of the buildings and shall be readily accessible. Water service connection shall be installed in accordance with the city's utility and engineering standards manual. (9) After a new water main has been laid and backfilled between joints it shall be flushed for a sufficient time to replace the water in the main at least twice. It shall then be pumped to a pressure of one hundred fifty (150) pounds per square inch and all visible leaks stopped by approved methods. (10) A leakage test shall be conducted at the above-mentioned pressure in accordance with the American Water Works Association's specification C600-93 and no installation will be accepted until the leakage is less than the number of gallons per hour as determined by the following formula: L = SDP1/2 133,200 L = allowable leakage, in gallons per hour S = length of pipe tested, in feet D = nominal diameter of main, in inches P = average pressure during test, in psi The test shall be maintained for a minimum of two (2) hours but it may be continued for one (1) additional hour if the leakage is equal to or greater than the amount allowable. Water supplied to the main during the test to maintain the required pressure shall be measured by a five-eighths-inch meter installed on the discharge side of the test pump, or by pumping from a calibrated container. A hose bib connection will be provided to accept the test gauge supplied by the city's utilities and engineering department. The test shall not vary by more than five (5) pounds per square inch for the duration of the test. The maximum allowable length of pipe for each test shall be two thousand (2,000) linear feet. Any questions pertaining to procedures used during the test shall be decided by the city engineer. (11) Sterilization. After the water mains have satisfied the leakage requirement they shall be disinfected in accordance with the applicable sections of the American Water Works Association's specification C-651, latest revision. On main breaks, cut-ins, etc., a liberal application of calcium hyphochlorite shall be made. (12) Mains will not be put into domestic service until after the necessary bacteriological samples have been approved by the county health department. Sampling points shall be provided at maximum intervals of one thousand (1,000) feet. (c) Materials. (1) Pipe. a. All pipe, fittings and appurtenances intended for conveying or transmitting water shall be designed for a minimum working pressure of one hundred fifty (150) pounds per square inch. b. Ductile iron pipe shall conform to the American Water Works Association's specification C151. Fittings shall be ductile or cast iron conforming to the American Water Works Association's C110, latest revision. All pipe and fittings shall be cement mortar lined conforming to the American Water Works Association's C104, latest revision. Asbestos cement pipe and PVC pressure pipe shall not be permitted on new construction of community water systems. c. Minimum wall thickness of ductile iron pipe shall be Class 51. Greater wall thickness shall be utilized as set forth in the American Water Works Association's C101, latest revision. d. Polyethylene pipe for water service lines shall conform to the American Water Works Association's C901-96, latest revision. The minimum wall thickness shall be SDR 9. Two-inch tubing shall be used for both one and one-half-inch and two-inch meter sets. Tubing shall be fully labeled with brand name and manufacturer, NSF seal, size, type of plastic material, and ASTM designation with which the tubing complies. e. Joints for bell and spigot ductile iron pipe and fitting shall conform to ANSI/AWWA Standard C111/A21.11 latest revision. Mechanical joint or push-on joint shall be rubber gasket compression-type. Special fittings and joints shall be considered for specific installation subject to the approval of the city engineer. f. Joints for polyethylene or polybutylene shall be of the compression type utilizing a totally confined grip seal and coupling nut. Stainless steel type stiffener insert shall also be used for tubing services. Other type joints may be considered for specific installations upon submission of specifications and approval by the city engineer. g. Pipe deflection. When it is necessary to deflect pipe from a straight line in either the vertical or horizontal plane or where long radius curves are permitted, the amount of deflection shall not exceed seventy-five (75) percent maximum deflection recommended by manufacturer. (2) Valves. a. Gate valves three (3) inches and larger shall comply with the American Water Works Association's specification C509, latest revision, and shall be iron body, bronze mounted, double disk, resilient seat, nonrising stem, parallel fit type, opening counterclockwise and shall have a minimum working pressure of two hundred (200) pounds per square inch. Nongeared valves shall be furnished with "O" ring packing (two (2) "O" rings.) Gate valves shall be used for all valves twelve (12) inches or smaller. Gate valves shall be installed in accordance with the city's utility and engineering standards manual. b. Butterfly valves shall comply with the American Water Works Association's specification C504-80, latest revision, and shall be cast-iron body with a minimum working pressure of two hundred fifty (250) pounds per square inch. c. Meter valves shall be of bronze construction in conformance with ASTM specification B-62, latest revision. Meter valves for meters one (1) inch and less shall be equipped with a coupling knot on the outlet side. Valves of one and one-half- and two-inch meters shall be flanged on the outlet side. Meter valves two (2) inches and under shall be as manufactured by the Ford Company, or their approved equal. (3) Valve boxes shall be telescoping plastic valve box not less than five-inch inside diameters and with locking cast-iron covers marked "water," as shown in the city's utility and engineering standards manual. (4) Fire hydrants shall be safety flange construction, cast-iron body, fully bronze mounted, suitable for a working pressure of one hundred fifty (150) pounds per square inch and shall be compression-type with 5¼-inch valve opening and fitted with two (2) 2½-inch hose connections and one (1) pumper nozzle meeting the requirements of the American Water Works Association's specification C502, latest revision. Hydrants shall be equipped with six-inch mechanical joint bases and have bury lengths of three (3) feet six (6) inches. The hydrant connection to the water main shall include a six-inch diameter gate valve. The hydrant shoe and gate valve shall be mechanically restrained to the water main tee. Fire hydrants shall be made by the American-Darling Company or Mueller Company, Model No. 423, or approved equal. Hydrants shall be painted a color corresponding to flow capacity as designated by the insurance services office. (5) Meters and miscellaneous appurtenances. a. All water meters shall conform to the requirements of the American Water Works Association's specification C700, latest revision, for cold water meters, all types. They shall have measurements in gallons and be round reading or straight reading up to and including the two-inch size. Installation shall be in accordance with the city's utility and engineering standards manual. Small residential meters shall be five-eighths inch by three-fourths inch, six-spindle, round reading or straight reading in gallons. Oil enclosed registers are optional. All other meters shall be no less than the size consistent with the anticipated maximum water demand of the customer and capacity rating of the meted. The size of the building service line shown on the architect's plan shall not be used as a criterion for the size of the meter. b. Corporation stops shall be installed at the main for all service connections less than two (2) inches in diameter and shall be manufactured of brass alloy in conformance with ASTM specification B-62, latest revision. Corporation stops shall be as manufactured by the Ford company, or approved equal. (6) Tapping sleeves and valves. a. Steel tapping sleeves shall have a welded steel body with flat faced steel flange, recessed for a tapping valve, in accordance with MSS-SP6-60. Gaskets shall be neoprene "O" ring type with some type of gasket restraint incorporated in the sleeve. Test plug shall be provided on the outlet throat. b. Cast iron tapping sleeves shall be of the mechanical joint type having a flat faced cast iron flange, recessed for a tapping valve. All end and side gaskets shall be totally confined. The throat section of taping sleeves through twelve-inch size shall conform to MSS-SP6-60. Test plug shall be provided on the outlet throat. c. Minimum tap sizes for water transmission lines 12" through 16" | 6" tap 18" through 30" | 8" tap 30" through 3" | 10" tap 42" and larger | 12" tap d. Tapping gate valves four (4) inches and larger shall comply with AWWA Standard C500 latest revision and shall comply with paragraph e. below. The valve port shall be free and full to allow clutter passage without interference. e. All gate valves are to be iron body, bronze, mounted, double disc, resilient seat nonrising stem, parallel fit type, opening left (counter clockwise). Nongeared valves shall be furnished with "O" rings packing (two (2) "O" rings). (7) Air release valve. a. Air release valves shall be of a type comprising a special float enclosed in the valve body with attached lever for opening and closing the air discharge port. Access to the ball float and interior discharge vent seat shall be provided by means of a bolted flange as made by Val Matic or approved equal. b. The design of the float and level shall be such as to insure opening of valve port under 150 PSI working pressure. The assembly shall not leak nor shall the valve stick under service conditions. (8) Detector check valves with LA pattern low flow bypass meter must meet Underwriter's Laboratories and Factory Mutual approvals and shall comply with the following: a. Detector check valve to be galvanized cast iron body full opening with removal cover for inspection. The mainline valve shall automatically open upon a pressure loss difference of approximately 1.5 PSI. b. Internal working parts shall be readily accessible for repair removal or replacement without removal of the valve from the pipeline. c. Internal working parts shall be readily accessible for repair removal or replacement without removal of bronze or stainless steel material. d. Seating surface shall be bronze metal to metal and may be integral or a separate ring fastened securely to the disc. e. Detector check valves to four (4) inches = ten (10) inches shall have minimum working pressure of 175 PSI and be tested at 3050 PSI. f. Meter low flow bypass line shall contain check valve, fittings and piping of bronze or stainless steel materials. Meter size per manufacturer's requirements to meet displacement water meter standard per above.

(Ord. No. 115-86, § 211.07, 7-10-86; Ord. No. 159-87, § 211.07, 6-11-87; Ord. No. 138-90, § 4, 1-10-91; Ord. No. 122-94, § 5, 5-26-94; Ord. No. 2001-023, § 3, 6-28-01; Ord. No. 2002-034, § 5, 11-14-02)

Ask a question about Coconut Creek law

Corpus searches the Coconut Creek sections it holds and shows the ones that match, with their citations. Free, no sign-in.