Sec. 13-256. - Sanitary sewers.

A system of sanitary sewers together with all necessary pumping stations and appurtenances shall be provided to serve all parcels of the subdivision. The system shall be designed to accommodate all reasonably anticipated wastewater flows from construction activities and occupants. The collection system shall conduct the wastewater directly or indirectly through sewers of adequate capacity to an approved treatment facility. (1) Sanitary sewage disposal. Where a public sanitary sewer is within one thousand (1,000) feet of the subdivision, the developer shall connect with the sewer and provide a connection to each lot, providing: a. Such sanitary wastewater system shall be installed prior to the installation of the street pavement, if possible. b. The city commission may require the installation of sanitary wastewater facilities which are in excess of the subdivision design needs and mutually establish an equitable reimbursement program with the developer. c. Where a public sanitary sewer is not accessible, the subdivision may be serviced by a disposal plant system or by septic tanks, if approved by applicable county and state agencies. If such alternative is not approved, the subdivision plat shall not be approved until a public sanitary sewer is available for connection. (2) Standards of design and construction. The wastewater collection system shall conform to all requirements and/or minimum standards of the applicable state and county agencies. Design shall be in essential compliance with the Sewage Guide issued by the Florida Department of Health. a. Gravity wastewater lines shall be installed in the center of the right-of-way or easement except that double main systems may be installed on state roads or other wide right-of-ways. The minimum size for wastewater lines is eight (8) inches. b. Wastewater lateral services shall be provided for connection to each lot and shall be installed in accordance with the alternate methods, where applicable, pursuant to the city's utility and engineering standards manual. The minimum size for a wastewater lateral service is six (6) inches and the maximum length of service lateral shall be one hundred fifty (150) feet. Service laterals shall not be permitted through manhole walls. c. Native and imported materials and back-fills beneath and around manholes or other underground structures shall be mechanically compacted in lifts of no larger than eight (8) inches thick or by other approved methods to a density of ninety-six (96) percent maximum density as determined by AASHTO T-180. Testing of backfill will be made to verify the degree of compaction of the fill material with locations and actual number of tests determined by the city engineer. d. Force mains shall generally be installed at the north or west edges of the street pavement, never under the sidewalk locations and shall be designed and constructed in conformance to the city's utility and engineering standards manual materials conforming to those indicated for water mains. (Ref. Section 13-242) Test of force mains shall be in conformance with section 13-242. Upon completion of the hydrostatic testing all force main piping shall be flushed with a sufficient amount of clear water to displace test water. Force main valves shall be installed so that the maximum allowable length of pipe between any two (2) valves shall be no longer than one thousand (1,000) feet. e. In all cases where wastewater lines cross water lines, whether above or below, with a distance of less than eighteen (18) inches between the outside walls of the pipes, the sewer shall be cast-iron or concrete encased PVC pipe for a distance of at least ten (10) feet on either side of the point of crossing. Sewers, including force mains which parallel water mains, shall have a minimum ten-foot horizontal separation from water mains. Where the ten-foot minimum horizontal separation cannot be attained, both water and sewer mains shall be ductile iron or concrete-encased PVC pipe until the ten-foot clearance is attained. f. Pumping stations shall be designed such that they will be compatible with the existing lift and pumping stations of the city. Stations shall consist of a minimum of two (2) totally submersible sewage pumps as manufactured by EMU, FLYGT or other approved manufacturer. Each pump shall be equipped with three-phase, sixty-cycle electric motors. For a pump station with a relatively high design capacity, an emergency generator shall be required, as determined by the city engineer. Pumping control panel shall be equipped with alarm and alarm light. g. Pump stations shall also include radio telemetry RTU (remote terminal units) as manufactured by the city's approved manufacturer with antennas, pressure transducers, HOA (hand off automatic) switches, pressure switches and other equipment that are compatible with the city's radio telemetry operation. h. Equipment such as valves and meters for use in pumping stations shall be similar to those used in existing city pump stations. The city reserves the right to reject any and all equipment and/or materials deemed by the city engineer to be inappropriate or of unacceptable quality. i. A six-foot high fence with a fourteen-foot wide double gate shall be provided for the pump station enclosure. The access drive shall be a minimum of twelve (12) feet wide. The length of access drive shall be a minimum of eighteen (18) feet in addition to providing adequate clearance from the pedestrian sidewalk. (3) Materials. a. Gravity sewers and house connection shall be polyvinyl chloride pipe (PVC) SDR 35, conforming to ASTM D 3034-73 or the latest revision with the additional requirement that pipe out-of-round in excess of the following tolerances will be rejected: Pipe Size (in inches) | Maximum Variation (in inches) 6, 8, & 10 | ¼ 12 | 5/16 15 | ⅜ Over 15 | ½ Maximum difference in side ordinate (as measured from the concave side of the pipe) shall not exceed one-sixteenth inch per foot of length. The inside diameter shall be measured at right angles. b. Precast concrete manholes shall conform with the requirements of ASTM C-478-70, latest revision, except that the minimum thickness for the shell and base will be eight (8) inches. The precast base shall be cast monolithically with the bottom section of the manhole well. The base slab shall be extended to a minimum of six (6) inches from the outside wall of the manholes. Lifting holes through the structures shall not be permitted. Minimum height of base section shall be three (3) feet from the bottom of base slab. Manhole sections shall be joined with a mastic compound or a round compression ring of neoprene material set in annual spaces cast into the spigot and of a bell spigot type joint. The mastic compound or ring shall form a water tight joint. All precast manhole sections, as delivered to the job site, shall be unpatched and shall bear the stamp of a certified engineering testing laboratory, certifying that the manhole sections meet the requirements of ASTM standard C-478 for concrete strength, steel reinforcement area and placement, and appearance when manufactured. c. Pipes connecting to manholes shall be provided with flexible connections as designated in Figure 200A of the Utility and Engineering Standards Manual. d. Two (2) coats (each a different color) of Koppers 300-M or approved equal shall be applied to the inside and outside surfaces of all manholes. e. Castings shall be of close-grained gray cast iron conforming to ASTM A-48, Class 30 iron. f. Leakage testing may be required on part or all gravity sewer piping as directed by the city engineer. Pipe joints shall sustain a maximum limit of 0.16 gallon per hour per inch-diameter per one hundred (100) feet when field tested. Infiltration tests shall be performed on sections of gravity sewer pipe that are predominantly below the surrounding water table. At the discretion of the city engineer, exfiltration tests shall be performed on sections of gravity sewer pipe that are predominantly above the surrounding water table. The developer shall notify the city engineer prior to all testing activities. The engineer of record shall provide the city engineer with certification that all sections of the gravity sewer system have passed leakage testing. The pipe test section may be filled twenty-four (24) hours prior to the time of exfiltration testing, if desired, to permit normal absorption into the pipe walls to take place. g. Lamping and/or television inspection shall be performed on all gravity sewer mains. The gravity system shall be watertight, free of debris, with manhole tops set to the permanent grade and position. Any defect disclosed during inspection must be corrected by the developer prior to the city's acceptance of the sewer line. h. Mandrel test. At the discretion of the city engineer, the developer shall test designated lines for excessive deflection. Maximum deflection shall be no more than seven and one-half (7.5) percent reduction in diameter due to manufacturing and installation imperfection. i. All service connection footage included in the test section and subjected to the minimum head specified, shall be taken into account in computing allowable leakage.

(Ord. No. 115-86, § 211.08, 7-10-86; Ord. No. 159-87, § 211.08, 6-11-87; Ord. No. 138-90, § 4, 1-10-91; Ord. No. 122-94, § 5, 5-26-94; Ord. No. 2001-023, § 3, 6-28-01; Ord. No. 2002-034, § 5, 11-14-02)

Ask a question about Coconut Creek law

Corpus searches the Coconut Creek sections it holds and shows the ones that match, with their citations. Free, no sign-in.