Sec. 13-258. - Stormwater drainage.

(a) A stormwater drainage system shall be provided that will drain the entire subdivision to positive outlets that can be legally maintained in permanent use or into a public drainage system of adequate capacity which discharges into such positive outlets, including all rights-of-way, easements and necessary construction at no expense to the city. Side ditches along public roads shall not necessarily be considered as such public drainage systems or positive outlets. Dry well catch basins shall in no case be permitted. (b) Standards of design and construction. The drainage shall be designed by accepted engineering principles and in accordance with the following design criteria unless required otherwise by the above governmental agencies: (1) Rational formula (Q = ACI). Q = Runoff in cubic feet per second A = Discharge area in acres C = Coefficient of runoff I = Rainfall intensity in inches per hour (2) Coefficient of runoff (C) shall be 0.8 for paved and roof areas and 0.4 for grassed areas. The coefficient of runoff for other areas shall be determined by the engineer of record by considering vegetation, slope, soil type and seasonal high groundwater elevation. (3) A five-year design storm event shall be used for all local streets, minor collectors and other subdivision drainage. However, a ten-year design storm event shall be used for all major collector and arterial roads. Rainfall intensities shall be based on United States Weather Bureau Technical Paper No. 25 as it applies to Zone 10 (Miami). (4) Manning's "N" shall be 0.013 for concrete pipe or fully paved corrugated metal pipe and 0.024 for corrugated metal pipe. (5) For minimum swale or gutter gradient refer to section 13-239(a). (6) The minimum size pipe allowed shall be fifteen (15) inches in diameter. (7) The minimum canal width, as measured along the surface of the design water level, shall be sixty (60) feet. (8) Design computations shall be submitted with drainage plans to be reviewed by the city engineer prior to the city approving such plans for construction. The city engineer may permit other design criteria to be used or may require the developer to use criteria other than that given above. (9) All drainage pipe in the public right-of-way shall have a minimum of eighteen (18) inches of cover, unless otherwise approved by the city engineer. (c) A yard drainage system shall be provided that will adequately drain any stormwater runoff away from buildings and structures. The minimum slope for overland flow shall be 0.3 percent. Swales may be used in a yard drainage system as noted in section 13-259. All yard drainage plans shall include the following notes: (1) No trees or berms are to be located within five (5) feet of the centerline of any swale. (2) No berms shall impede the overland flow by running parallel to or across any swales. (3) Sidewalks and driveways constructed through a typical roadside swale shall be constructed with a transverse grade at two (2) inches below the tie-in edge of pavement elevation. The typical adjacent six (6) inches deep swale shall be graded to match the sidewalk. Yard drainage plans must be submitted to the city engineer for approval. The yard drainage plans shall be incorporated into the landscape plans and building plans as a point of information to the landscape and building contractor. (d) Inlets, headwalls, manholes and other drainage structures shall be of a design approved by the city engineer. Headwalls shall be provided for all drainage outfalls. Generally, structures and facilities designed in accordance with the state department of transportation's Standard Specifications for Road and Bridge Construction, latest edition, will be satisfactory; however, the city engineer may permit the use of other designs or require the use of other designs. (e) All stormwater drainage materials and construction shall be in accordance with the state department of transportation's Standard Specifications for Road and Bridge Construction, latest edition. (f) All drainage pipe installation under and parallel to the roadway in present or planned paved area shall be reinforced concrete, conforming to ASTM specification C301. (g) Drainage structures and manholes shall not have less than a three-inch inside dimension between opposing walls or a four-inch diameter. The structures shall meet the requirements of ASTM Standard C-478. Walls shall be not less than six (6) inches thick. Top and bottom slabs shall be not less than eight (8) inches thick. The base slab shall be extended to a minimum of six (6) inches from the outside wall of the structure.

(Ord. No. 115-86, § 211.0901, 7-10-86; Ord. No. 159-87, § 211.0901, 6-11-87; Ord. No. 122-94, § 5, 5-26-94)

Ask a question about Coconut Creek law

Corpus searches the Coconut Creek sections it holds and shows the ones that match, with their citations. Free, no sign-in.