1205.3. - ROOFS.

(a) The roofs of buildings and structures shall be designed and constructed to withstand pressures, acting outward normal to the roof surface equal to 1¼ times the pressures specified in section 1205.1. The height is to be taken as the vertical distance from the average elevation of the ground adjoining the building to the average elevation of the roof. (b) Roofs or sections of roofs with slopes greater than 30 degrees shall be designed to withstand pressures, acting inward normal to the surface, equal to these specified in Section 1205.1 and applied to the windward slope only. (c) Parapets, overhanging eaves and cornices shall be designed and constructed to withstand outward pressures equal to twice those specified in Section 1205.1.