1205.4. - CHIMNEYS, TANKS AND TOWERS.

(a) Chimneys, tanks, solid towers and similar structures shall be designed and constructed to withstand the pressures specified in Section 1205.1 multiplied by the following factors: Shape in Horizontal Cross Section | Factor Square or rectangular ..... | 1.00 Hexagonal or octagonal ..... | 0.80 Round or elliptical ..... | 0.60 (b) Radio towers and other towers of trussed construction shall be designed to withstand the wind pressures specified in Section 1205.1 multiplied by the following factors: Tower on total projected area of elements, windward side Wind normal to one side 3 or 4 cornered tower with flat or angular sections | 2.20 Wind on corner 3-cornered structure | 2.20 4-cornered metal structure | 2.40 4-cornered wood structure | 2.60 Individual elements on projected area Cylindrical Sections 2 in. or less in diameter | 1.00 Over 2 in. in diameter | 0.80 Flat or angular sections | 1.30