For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6.17.00 — UTILITIES

Code of Ordinances of the City of Kennesaw, Georgia (Codified through Ordinance No. 2026-06, enacted March 2, 2026. (Supp. No. 37)) · Kennesaw Municipal Code, App. A, ch. 6, § 6.17.00

Corpus is an independent public-information project, not the official City of Kennesaw website. Stable reference: corpuslaw.us/code/bce77cd3-ab1b-4c4d-b6e2-097339626d95

6.17.00 - UTILITIES

City of Kennesaw has adopted the Georgia Department of Transportation, Utility Accommodation Policy and Standards, Section 3 - Rules for Issuing Permits (as may be amended from time to time). Please see Volume 2, Section 508, Materials Specifications and Standard Details. 1. For damage prevention purposes, all utility locations within a street right-of-way shall correspond to the utility location cross section in Standard Details 80, 80a, 80b, 81, 81a and 82. 2. On residential streets constructed without curb and gutter, the utility depths shall be increased by one foot to allow for the realignment of the ditches without damaging the utilities. The developer is encouraged to coordinate with the City of Kennesaw Public Works. 3. Southern Bell requests to be moved from 18" BOC (back of curb) to 7½' BOC and from 24" deep to 30" deep to accommodate the gas service crossings. 4. CATV requests to be moved from 5" BOC to 12" BOC and from 18" deep to 24" deep. 5. Power requests to be moved from 8' BOC to 9' BOC with power transformer being flush with back of the right-of-way. 6. Gas requests to remain at 36" BOC and 30" deep and will raise service laterals from 30" deep to 24" deep. 7. Water requests to remain at 5' BOC and 42" deep. 8. Utility companies may utilize a joint trench for utility installation. If a joint trench is used, its depth shall be that of the utility in the trench required to place its lines at the greatest depth. Joint trench placement may be specified or random placements. 9. All contractors, developers, utility companies, and the "general digging public" are encouraged to abide by the OCGA 9 (25). The UPC number is (404) 623-4344; (800) 282-7411. 10. All privately owned equipment or utilities, with the exception of residential mailboxes, shall be allowed on public right-of-way by special permit only. A special permit must be approved by the Public Work Director and Kennesaw Building Official. 11. Any utility installed on the City's right-of-way under special permit shall be equipped with a tracing or locating mechanism. As an example, any non-conductive conduit shall be equipped with a minimum size 16 gauge corrosion-resistant tracer wire to aid in locating the utility. The wire shall extend along the tributary conduit to a point four feet off of the right-of-way. 12. Water and sewer service lateral locations are to be permanently marked on the curb under which they cross. 13. Any contractor operating within the City shall sign a statement to acknowledge receipt of this new regulation as a condition of obtaining a business license to operate within City. Contractors shall provide a 24-hour contact telephone number to the Georgia UPC. 14. Responsibility for the location of any utility placed on the City right-of-way under special permit rests solely upon the owner of the utility. Any damage repair to non-permitted utilities shall be the responsibility of the owner of the utility. 15. The design and construction specifications for all-public water and sanitary sewer facilities shall conform to the specifications of the Cobb County Water System or applicable authority, i.e., water meters should back-up to the property line. 16. Storm drains and cul-de-sacs shall off-set the right-of-way to accommodate utilities. See Standard Details 80 and 81. 17. All streetlights shall be placed at the property line. 18. The standard color codes adopted by the American Public Works Association and the Georgia Utilities Coordinating Committee shall be utilized for any necessary marking of underground utility lines. The color scheme is as follows: Red | Electric Yellow | Gas/Oil Orange | Communications/Cable TV Blue | Water Green | Sewer White | Proposed Excavations Pink | Surveyors 19. All utility manholes and valve boxes shall be brought to the finished grade within the roadway section. Manhole covers and splice boxes placed within the sidewalk zone shall be constructed to be flush mounted with the finished sidewalk. 20. Utility poles and transformers shall be located as near as possible to the frontage line. Wherever practical, utility poles or transformers shall not be located on the same lot corner as water service.

Ask a question about Kennesaw law

Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.